Inspection Detail
Inspection: 310577093 - B & B Electric Company Inc.
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
B & B Electric Company Inc.
815 Dix Dam Rd
Harrodsburg, KY 40330
Mailing Address:
1460 Sunshine Lane, Lexington, KY 40505
Union Status: Union
SIC:1629
NAICS: 237130/Power and Communication Line and Related Structures Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference:
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/03/2016
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101869907 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | ||||||
Initial Penalty | $12,600 | $0 | $0 | $0 | $0 | $12,600 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260021 B02 | 09/25/2007 | 10/01/2007 | $0 | $6,300 | $0 | 10/11/2007 | D - Govt Dismissed | Citation has been deleted. |
2. | 01002 | Serious | 19260951 B01 | 09/25/2007 | 10/01/2007 | $0 | $6,300 | $0 | 10/11/2007 | D - Govt Dismissed | Citation has been deleted. |
Investigation Summary
On March 27, 2007, an employee was bolting an electric power transmission tower at a height of approximately 70 feet above ground. The employee unhooked lanyard to change locations, lost his grip. He fell to the ground and was killed.
Keywords: FRACTURE, BACK, LANYARD, FALL, FALL PROTECTION, TRANSMISSION TOWER, WORK SURFACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 310577093 | Fatality | Fracture | Electrical power installers and repairers |