Powered by GoogleTranslate

Inspection Detail

Inspection: 310495585 - Xcel Mechanical Systems Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 310495585
Report ID: 0950642
Date Opened: 07/02/2009

Site Address:
Xcel Mechanical Systems Inc
6100 S Central Ave
Los Angeles, CA 90001

Mailing Address:
1710 West 130th Street, Gardena, CA 90249

Union Status: Union

SIC:1711

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/30/2009

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/30/2010


Related Activity
Type Activity Nr Safety Health
Accident 102476405
Accident 102620218
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $1,500 $0 $1,500
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3395 E01 11/30/2009 01/02/2010 $0 $750 $0 12/17/2009 F - Formal Settlement  
2. 01002 Other 3395 E03 11/30/2009 01/02/2010 $0 $750 $0 12/17/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202455820
Event: 06/26/2009
Employee Receives Injuries in Fall from Scaffold

On June 26, 2009, Employee #1 and a coworker were installing ductwork for an air conditioning system via a metal rolling scaffold with guardrails. The ductwork was placed on the rolling scaffold between the two employees. They could not see each other. The coworker asked Employee #1 for a cleat tool. After handing it to him, Employee #1 decided to seal the joint between the two ducts that they were resting on the platform. He was sitting with his back against the railing, when he suddenly lost his balance, likely from retrieving seal tubes, and fell approximately 7 ft to the ground. Employee 1 was transported to Saint Francis Hospital via an ambulance, where he was hospitalized for five days for second, third, fourth rib fractures, a right clavicle fracture, a right bruised lung and a concussion. He had additional surgery at Citrus Valley Medical Center, which involved the placement of an endobutton to repair the right clavicle fracture.

Keywords: FRACTURE, LUNG, SHOULDER, MOBILE SCAFFOLD, RIB, FALL, CONCUSSION, LOST BALANCE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310495585 Hospitalized injury Fracture Sheet metal worker apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close