Powered by GoogleTranslate

Inspection Detail

Inspection: 310494877 - Grand Auto Electric

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 310494877
Report ID: 0950642
Date Opened: 04/03/2009

Site Address:
Grand Auto Electric
425 W Chestnut Ave
Monrovia, CA 91016

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5531

NAICS: 441310/Automotive Parts and Accessories Stores


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/22/2009

Emphasis:

Case Closed: 05/18/2010


Related Activity
Type Activity Nr Safety Health
Accident 102475472
Accident 102475548
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 2 3 5
Initial Penalty $16,200 $0 $0 $5,610 $0 $21,810
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 07/30/2009 08/04/2009 $0 $5,000 $0 08/26/2009 F - Formal Settlement  
2. 01002 Other 3203 A 07/30/2009 09/01/2009 $0 $260 $0 08/26/2009 F - Formal Settlement  
3. 01003 Other 23400001 07/30/2009 09/01/2009 $0 $350 $0 08/26/2009 F - Formal Settlement  
4. 02001 Serious 5174 F 07/30/2009 08/09/2009 $0 $5,400 $0 08/26/2009 F - Formal Settlement  
5. 03001 Serious 5174 I 07/30/2009 08/09/2009 $0 $10,800 $0 08/26/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202455440
Event: 03/31/2009
Mechanic Is Burned in Combustible Dust Flash Fire

At around 11:40 a.m. on March 31, 2009, Employee #1, a mechanic with an electrical auto parts rebuilding facility, was operating an ARE Industries rotary bead blasting machine (Model Number HB 45, Serial Number 1871124) to clean used electrical auto parts. He loaded automotive starters and alternators into the machine and then started it. A flash fire erupted in the adjacent dust collection bag house. Flames from burning combustible aluminum dust emitted from a duct and burned Employee #1. He was hospitalized at Sherman Oaks Hospital, Grossman Burn Center for third-degree burns to his thighs and face. The investigation concluded that combustible dust had accumulated in the work area and that the bag house was located in the work area. Employee #1 refused to be interviewed; however, investigators interviewed his supervisor.

Keywords: BURN, DUCT, DUST, ALUMINUM DUST, FIRE, MACHINE OPERATOR, MECHANIC, DUST COLLECTOR, COMBUSTIBLE DUST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310494877 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close