Powered by GoogleTranslate

Inspection Detail

Inspection: 310479985 - Pike Electric, Inc.

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 310479985
Report ID: 0522500
Date Opened: 07/09/2007

Site Address:
Pike Electric, Inc.
13675 Sand Rock Road
Glenford, OH 43739

Mailing Address:
P.O. Box 868, Mount Airy, NC 27030

Union Status: NonUnion

SIC:4911

NAICS: 221122/Electric Power Distribution


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/19/2007

Emphasis: S:Electrical, S:Hwy Street Bridge Constr

Case Closed: 02/03/2009


Related Activity
Type Activity Nr Safety Health
Accident 100752823
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $14,000 $0 $0 $0 $0 $14,000
Current Penalty $10,000 $0 $0 $0 $0 $10,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100269 Q01 II 09/19/2007 09/29/2007 $10,000 $7,000 $0 I - Informal Settlement  
2. 01002 Serious 19100269 Q01 III 09/19/2007 09/29/2007 $7,000 $7,000 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200758472
Event: 07/09/2007
Employee Is Electrocuted by Overhead Power Lines

At approximately 11:15 a.m. on July 9, 2007, an employee, working with a four man crew, had installed a new pole and moved the lines to the new pole prior to the accident. The primary line had been covered with insulated line hoses and blankets. The crew positioned the equipment to remove the old pole. A choker was attached to the pole to lift the pole and the pole grabber on the line truck was hooked around the pole. The pole was then lifted approximately 12 to 18 inches up. The foreman then instructed the employee, a groundman, to cut off the pole with a chain saw. When the cut was made, the bottom of the pole kicked out toward the road, where the employee was standing. The employee tried to use his hands to push the pole back from hitting him. When the pole kicked out, the top of the pole contacted the energized primary line. The employee, who was not wearing required PPE, rubber gloves, was electrocuted.

Keywords: OVERHEAD POWER LINE, PPE, ELECTROCUTED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310479985 Fatality Electric Shock Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.