Inspection Detail
Inspection: 310468418 - Rampart Hydro Services Lp
Inspection Information - Office: Denver Area Office
Site Address:
Rampart Hydro Services Lp
Dia Runway 16l
Denver, CO 80249
Mailing Address:
530 Moon Clinton Road, Coraopolis, PA 15108
Union Status: NonUnion
SIC:4581
NAICS: 488119/Other Airport Operations
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/19/2007
Emphasis: S:Struck-By
Case Closed: 09/08/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101574754 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $0 | $0 | $0 | $2,500 | $0 | $2,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100132 A | 09/21/2007 | 09/29/2007 | $2,500 | $2,500 | $0 | 10/12/2007 | F - Formal Settlement | Citation has been deleted. |
2. | 01001B | Other | 19100132 D02 | 09/21/2007 | 08/03/2008 | $0 | $0 | $0 | 10/12/2007 | F - Formal Settlement | Citation has been deleted. |
3. | 01002 | Serious | 19100145 F05 | 09/21/2007 | 09/29/2007 | $2,500 | $2,500 | $0 | 10/12/2007 | F - Formal Settlement | Citation has been deleted. |
4. | 01003 | Other | 19100132 D02 | 09/21/2007 | 08/03/2008 | $2,500 | $0 | $0 | 10/12/2007 | F - Formal Settlement |
Investigation Summary
On August 6, 2007, Employee #1 was employed by a rubber removal contractor, and was operating a truck-mounted high pressure water sprayer that applied 36,000-psi of water to remove the rubber that remained on the runways when planes landed to increase the friction for landing planes. After concluding the night shift work, Employee #1 was measuring the runway square footage for the work accomplished or to determine the remaining work. The City of Denver operated two wire brush sweepers to sweep up any rubber residue, to prevent any residue from being sucked into the airplane engines. At about 5:00 a.m., when it was still dark, a sweeper (MB Companies, Model Number 4600-FMD-HP3, Serial Number 15-0446) was going one direction, but made an abrupt turn, striking and running over Employee #1. Employee #1 was wearing dark clothes and was not wearing a reflective vest. Employee #1 was killed.
Keywords: FRACTURE, AIRPORT, STRUCK BY, REFLECTIVE VEST, RUN OVER, SPRAYING RIG, SWEEPER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 310468418 | Fatality | Fracture | Occupation not reported |