Inspection Detail
Inspection: 310468103 - Leed Energy Services
Inspection Information - Office: Denver
Site Address:
Leed Energy Services
Near Wcr 46 And 29
Gilcrest, CO 80623
Mailing Address:
3770 Puritan Way Unit J, Frederick, CO 80516
Union Status: NonUnion
SIC:1389
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/20/2007
Emphasis: L:Oilgas, S:Struck-By
Case Closed: 06/13/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101574796 | ||
Referral | 201578960 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $7,500 | $0 | $0 | $0 | $0 | $7,500 |
Current Penalty | $5,000 | $0 | $0 | $1,000 | $0 | $6,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 01/16/2008 | 02/08/2008 | $5,000 | $5,000 | $0 | - | ||
2. | 01002 | Other | 5A0001 | 01/16/2008 | 02/08/2008 | $1,000 | $2,500 | $0 | I - Informal Settlement | ||
3. | 02001 | Other | 19100023 D01 | 01/16/2008 | 02/08/2008 | $0 | $0 | $0 | - |
Investigation Summary
At approximately 8:00 a.m. on July 25, 2007, an employee, a part of a crew was cleaning out an active well. Gas wells were cleaned periodically because it caused them to be more productive. The employee was operating the high pressure pump when a pocket of gas was released from the well. When the gas floated over to the high pressure pump it ignited and burned the employee. As the employee ran away, he ran into another gas pocket and thus received burns over 70 percent of his body. The employee was airlifted to a burn unit. The employee died after spending approximately six weeks in the hospital.
Keywords:burn, gas well, cleaning, ignition system, gas
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 310468103 | Fatality | Burn/Scald(Heat) | Occupation not reported |