Powered by GoogleTranslate

Inspection Detail

Inspection: 310440631 - Crestwood Midstream Partners Lp

Inspection Information - Office: Fort Worth Area Office

 

Inspection Nr: 310440631
Report ID: 0636900
Date Opened: 05/29/2007

Site Address:
Crestwood Midstream Partners Lp
2400 Cr 326
Cleburne, TX 76033

Mailing Address:
801 Cherry St, Suite 3700, Unit 19, Fort Worth, TX 76102

Union Status: NonUnion

SIC:4922

NAICS: 211111/Crude Petroleum and Natural Gas Extraction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/19/2007

Emphasis: L:Oilgas

Case Closed: 12/17/2007


Related Activity
Type Activity Nr Safety Health
Accident 100714690
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $4,500 $0 $0 $0 $0 $4,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 11/20/2007 12/17/2007 $4,500 $4,500 $0 -  

Investigation Summary

Investigation Nr: 200713147
Event: 05/25/2007
Employee Is Killed in Heat Exchanger Explosion

On May 25, 2007, an employee and a coworker, plant operators, were working the evening shift to ignite the heat exchanger. After four attempts, the coworker received the green light on the control panel. He gave a thumb's up sign to the employee to proceed. The employee was at the gas heater controls, bending over at the controls when the heat exchanger exploded. The employee was killed. No fire or flash was noted.

Keywords: EXPLOSION, HEAT EXCHANGER, STRUCK BY, FLYING OBJECT, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310440631 Fatality Bruise/Contus/Abras Power plant operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.