Powered by GoogleTranslate

Inspection Detail

Inspection: 310412390 - John O'Neill & Russell Meehan Dba

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 310412390
Report ID: 0950621
Date Opened: 05/10/2007

Site Address:
John O'Neill & Russell Meehan Dba
1195 Florin Rd
Sacramento, CA 95825

Mailing Address:
5714 Folsom Blvd #245, Sacramento, CA 95826

Union Status: NonUnion

SIC:1771

NAICS: 238140/Masonry Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/06/2007

Planning Guide: Safety-Construction

Emphasis: S:Construction (Cship)

Case Closed: 10/06/2022


Related Activity
Type Activity Nr Safety Health
Accident 362334070
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 3 2 5
Initial Penalty $24,300 $0 $0 $685 $0 $24,985
Current Penalty $24,300 $0 $0 $685 $0 $24,985
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 08/07/2007 09/10/2007 $275 $275 $0 08/30/2007 D - Govt Dismissed  
2. 01002 Other 1511 B 08/07/2007 08/24/2007 $410 $410 $0 08/30/2007 D - Govt Dismissed  
3. 02001 Serious 1509 A 08/07/2007 09/10/2007 $4,950 $4,950 $0 08/30/2007 D - Govt Dismissed  
4. 03001 Serious 1637 Q 08/07/2007 09/10/2007 $4,950 $4,950 $0 08/30/2007 D - Govt Dismissed  
5. 04001 Serious 2946 A 08/07/2007 09/10/2007 $14,400 $14,400 $0 08/30/2007 D - Govt Dismissed  

Investigation Summary

Investigation Nr: 202485314
Event: 05/10/2007
Employee Is Burned by Energized Electric Line

On May 10 , 2007, a plastering foreman and a coworker were working from the top level of a multiple story scaffold erected on the corner of a commercial building. The foreman was installing 10-foot-long galvanized "stucco stops" around the perimeter of the parapet wall. Needing an additional section, he walked around the corner of the building to where a small pile of stucco stops had been placed. He picked up one stop and began carrying it back, diagonally over his shoulder, to his work location when one end of the stop came in contact with an energized, overhead 12-kilovolt overhead power line. Protective devices on the line deenergized it, freeing the employee, but it took the coworker to keep him from rolling off the scaffold. The Sacramento City Fire Department responded and after rescuing the employee from the scaffold, arranged transportation to UC Davis Medical Center. The employee sustained serious burns over the upper part of his body for which he was hospitalized.

Keywords: BURN, SHOCK, ELECTRIC CABLE, STRUCK AGAINST, WORK SURFACE, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310412390 Hospitalized injury Electric Shock Supervisors; painters, paperhangers and plasterers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.