Inspection Detail
Inspection: 310400080 - Essilor Laboratories Of America, Inc.
Inspection Information - Office: Nc Department Of Labor - Winston-Salem
Site Address:
Essilor Laboratories Of America, Inc.
1909 North Church Street
Greensboro, NC 27405
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3851
NAICS: 339115/Ophthalmic Goods Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 03/15/2007
Emphasis: S:Program Improvement
Case Closed: 05/05/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100073519 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $525 | $0 | $0 | $0 | $0 | $525 |
| Current Penalty | $525 | $0 | $0 | $0 | $0 | $525 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100133 A01 | 04/05/2007 | 04/10/2007 | $525 | $525 | $0 | - | ||
| 2. | 02001 | Other | 19100037 B04 | 04/05/2007 | 04/10/2007 | $0 | $0 | $0 | - | ||
| 3. | 02002A | Other | 19101200 G01 | 04/05/2007 | 05/01/2007 | $0 | $0 | $0 | - | ||
| 4. | 02002B | Other | 19101200 H01 II | 04/05/2007 | 05/01/2007 | $0 | $0 | $0 | - | ||
| 5. | 02002C | Other | 19101200 H02 I | 04/05/2007 | 05/01/2007 | $0 | $0 | $0 | - | ||
| 6. | 02002D | Other | 19101200 H02 II | 04/05/2007 | 05/01/2007 | $0 | $0 | $0 | - | ||
| 7. | 02002E | Other | 19101200 H02 III | 04/05/2007 | 05/01/2007 | $0 | $0 | $0 | - |
Investigation Summary
On March 14, 2007, Employees #1 through #6 were working at a facility where ophthalmic goods such as ophthalmic frames, lenses, and sunglass lenses were manufactured. A high-index plastic lens with a refractive index of 1.74 was being ground without a water wash. The plastic overheated and emitted a small amount of hydrogen sulfide gas, which the employees inhaled. The six employees displayed a physical reaction to the strong odor. Employees #1 and #2 were examined at the scene and determined not to need further treatment. Employees #3 through #6 were taken to the hospital, where they were examined and released. (The original form did not list Employees #3 through #6 on an injury line.)
Keywords: LUNG, VAPOR, HYDROGEN SULFIDE, INHALATION, POISONING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310400080 | Non Hospitalized injury | Other | Occupation not reported | ||
| 2 | 310400080 | Non Hospitalized injury | Other | Occupation not reported |