Inspection Detail
Inspection: 310202197 - San Cristobal Distributing
Inspection Information - Office: Van Nuys District Office
Site Address:
San Cristobal Distributing
20991 South Mountain Rd.
Santa Paula, CA 93060
Mailing Address:
3645 Saviers Rd., Ste. 14, Oxnard, CA 93033
Union Status: NonUnion
SIC:0161
NAICS: 111219/Other Vegetable (except Potato) and Melon Farming
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/19/2008
Emphasis:
Case Closed: 10/02/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102540788 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $15,750 | $0 | $0 | $670 | $0 | $16,420 |
| Current Penalty | $0 | $0 | $0 | $7,670 | $0 | $7,670 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 341 C01 | 12/19/2008 | 01/06/2009 | $560 | $560 | $0 | 01/15/2009 | F - Formal Settlement | |
| 2. | 01002 | Other | 1509 B | 12/19/2008 | 01/05/2009 | $110 | $110 | $0 | 01/15/2009 | J - ALJ Decision | |
| 3. | 02001 | Other | 5418 C | 12/19/2008 | 12/29/2008 | $7,000 | $15,750 | $0 | 01/15/2009 | J - ALJ Decision |
Investigation Summary
On June 22, 2008, Employees #1, #2, #3 and #4 were creating a drainage system for the farm. This drainage system would divert water away from a ravine. The water would be collected in a sump. The employees were directed to install the drainage system by the owner of the company and the owner's wife. The owner stated that he had requested the employees to excavate a sump and install a plastic lining to be purchased from a hardware store. According to the employees, the owner told them to utilize the 55 gallon drums located on the property at part of the sump system. The drums were to be cut on the side to insert piping into the drums. The employees were in the welding shed at the time of the incident. Based on the interviews conducted, the employees operating the Oxy-Acetylene torch system utilized the system to attempt to cut a hole in the barrel. The drum was not cleaned and no measures were taken to ensure that the drum was free of ignitable chemicals. The volatile organic compounds within the barrel were ignited by the torch. The resulting fire burned all 6 injured persons. Employee #2 was killed. Employees #1, #3 and #4 were hospitalized for burns. Interviews were conducted of three remaining employees, the owner and fire investigator. The investigation concluded that the drum containing Volatile organic compounds was ignited by the Oxy-Acetylene system as the flame approached the drum.
Keywords: BURN, DRUM, WELDER, EXPLOSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310202197 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction | ||
| 2 | 310202197 | Fatality | Burn/Scald(Heat) | Laborers, except construction | ||
| 3 | 310202197 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction | ||
| 4 | 310202197 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |
Translate