Inspection Detail
Inspection: 310201827 - Aerospace Service & Controls, Inc. Dba Asc Process
Inspection Information - Office: Van Nuys District Office
Site Address: 
			   Aerospace Service & Controls, Inc. Dba Asc Process
			   14062 Balboa Bl.
Sylmar, CA 91342
Mailing Address: 
			   , ,  00000
Union Status: NonUnion
SIC:3443
NAICS: 332410/Power Boiler and Heat Exchanger Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/04/2008
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/23/2009
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 102540226 | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 6 | 7 | |||
| Current Violations | 1 | 6 | 7 | |||
| Initial Penalty | $16,200 | $0 | $0 | $5,805 | $0 | $22,005 | 
| Current Penalty | $650 | $0 | $0 | $805 | $0 | $1,455 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 11/07/2008 | 11/13/2008 | $0 | $5,000 | $0 | 12/08/2008 | F - Formal Settlement | |
| 2. | 01002 | Other | 3203 B02 | 11/07/2008 | 11/13/2008 | $325 | $325 | $0 | 12/08/2008 | F - Formal Settlement | |
| 3. | 01003 | Other | 6151 C02 | 11/07/2008 | 11/28/2008 | $160 | $160 | $0 | 12/08/2008 | F - Formal Settlement | |
| 4. | 01004 | Other | 3400 C | 11/07/2008 | 11/28/2008 | $160 | $160 | $0 | 12/08/2008 | F - Formal Settlement | |
| 5. | 01005 | Other | 3203 A05 | 11/07/2008 | 11/28/2008 | $160 | $160 | $0 | 12/08/2008 | F - Formal Settlement | |
| 6. | 01006 | Other | 14300032 A01 | 07/18/2008 | 08/06/2008 | $0 | $0 | $0 | - | ||
| 7. | 02001 | Serious | 4313 | 11/07/2008 | 11/13/2008 | $650 | $16,200 | $0 | 12/08/2008 | F - Formal Settlement | 
Investigation Summary
At approximately 8:30 a.m. on May 9, 2008, an employee was working as an electrician at a medium-size business that fabricated structural metal products. It had 81 employees. He had been working there for 11 months, carrying out the duties of an electrician, including performing wiring tasks. At the time of the accident, he was performing a regularly assigned task of smoothing the rough edges on a metal plate for use in a larger manufactured product. Although he was working near other employees, there were no eyewitnesses. He was using a 20-inch standalone disc grinder to remove rough edges and burrs from a piece of metal plate. He was using both hands to hold the piece, and his hands were bare. As he held the piece, the ring finger and small finger on his left hand went in between the edge of a metal table and the disc. The ring finger sustained an avulsion, with an amputation to the medial section of the interphalangeal joint. The small finger sustained an avulsion, with bone loss to the distal interphalangeal joint. The employee was transported by a fellow employee to Providence Holy Cross Medical Center in Mission Hills, California. Interviews were conducted of the Production Manager, two mechanics, an electrician, an electrical supervisor, a human resources assistant, and the injured worker. The investigation concluded that the employee was able to place fingers between the revolving disc and edge of table. As a result, the Division did issue a Serious accident-related citation, CCR, Title 8, GISO 4313, and three Regulatory and three General citations.
Keywords: GRINDER, AMPUTATED, PPE, FINGER, GLOVE, DEGLOVED, ELECTRICIAN, METAL SHEET, CAUGHT BETWEEN, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 310201827 | Hospitalized injury | Amputation | Electricians | 
 Translate