Powered by GoogleTranslate

Inspection Detail

Inspection: 310200233 - Specialty Crane & Rigging Corp.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 310200233
Report ID: 0950643
Date Opened: 02/15/2008

Site Address:
Specialty Crane & Rigging Corp.
1171 More Ranch Rd.
Santa Barbara, CA 93111

Mailing Address:
1 South Fairview Ave., Goleta, CA 93117

Union Status: NonUnion

SIC:4922

NAICS: 486210/Pipeline Transportation of Natural Gas


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/15/2008

Emphasis:

Case Closed: 06/22/2009


Related Activity
Type Activity Nr Safety Health
Accident 102539145
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $3,600 $0 $0 $5,000 $0 $8,600
Current Penalty $0 $0 $0 $1,150 $0 $1,150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 03/21/2008 03/31/2008 $750 $5,000 $0 04/03/2008 W - Empr Withdrew  
2. 02001 Other 3328 A 07/25/2008 08/04/2008 $400 $3,600 $0 08/04/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202466264
Event: 02/09/2008
Employee Fractures Ankle When Struck by Hoisting Device Load

At approximately 10:40 a.m. on February 9, 2008, Employee #1 and three coworkers were moving a 2,800-lb compressor using a shop fabricated hoisting device. The device consisted of two uprights, an 8-inch by 20-ft I-beam, two rollers and two chain falls. They rigged the compressor to the hoisting device using nylon slings. They then hoisted the compressor up two inches from the concrete floor and began pushing/pulling the compressor horizontally along the I-beam. They encountered a two inch pipe extending up from the floor, inhibiting the horizontal movement of the compressor. They tried to work the compressor around the pipe, but redistributing the weight of the compressor on the beam caused the hoisting apparatus to leave its vertical/horizontal balance. The hoisting device and beam tipped over, falling onto Employee #1, and fracturing his right ankle. He was hospitalized for treatment.

Keywords: COMPRESSOR, FRACTURE, HOISTING MECHANISM, STRUCK BY, FALLING OBJECT, ANKLE, UNSTABLE LOAD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310200233 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close