Type Activity Nr Safety Health
Accident 102538246
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $18,000 $0 $0 $785 $0 $18,785
Current Penalty $14,400 $0 $0 $785 $0 $15,185
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3661 C 01/25/2008 02/15/2008 $240 $240 $0 -  
2. 02001 Other 6151 E02 06/17/2008 07/07/2008 $135 $135 $0 -  
3. 02002 Other 3314 J01 06/17/2008 07/07/2008 $410 $410 $0 -  
4. 03001 Serious 3314 F 06/17/2008 07/07/2008 $14,400 $18,000 $0 06/30/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 310199997
Event: 12/18/2007
Employee Loses Finger in Tool Changer

At 3:20 p.m. on December 18, 2007 , Employee #1, was performing a regularly assigned task of set up procedures in an attempt to set up a new vertical milling machine. Employee #1 was assisting a coworker to set up a newly purchased machine by a client. Both Employee #1 and his coworker were at the site of clients' building where the packaging material had been removed. Prior to incident employee #1 was pointing his finger at the tool changer arm which rotated counterclockwise parallel to the floor of the machine. The coworker was at the control panel initiating start up procedures and tolerances for parts. Employee #1 put his hand in close proximity to the tool changer arm to point out to hs coworker, there was an unwanted variation in the movement. The coworker hit some buttons at same time Employee #1 had his finger within the swing zone of arm. The arm moved very fast and severed the upper portion of his right index finger. The injured employee was working within close proximity to his coworker who was operating the controls. Employee #1 was transported to the emergency room at Henry Mayo Hospital in Valencia where his finger was amputated. The investigation concluded that Employee #1 did not receive any type of training on control of hazardous energy, and was considerably involved in setting-up and adjusting the milling machine without any training.

Keywords: AMPUTATED, PANEL, FINGER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310199997 Non Hospitalized injury Amputation Numerical control machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.