Powered by GoogleTranslate

Inspection Detail

Inspection: 310198569 - Merle Norman Cosmetics, Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 310198569
Report ID: 0950643
Date Opened: 09/04/2007

Site Address:
Merle Norman Cosmetics, Inc.
15180 Bledsoe St.
Sylmar, CA 91342

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5122

NAICS: 446120/ Cosmetics, Beauty Supplies, and Perfume Stores


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/09/2007

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/10/2008


Related Activity
Type Activity Nr Safety Health
Accident 101119998
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $1,335 $0 $1,335
Current Penalty $0 $0 $0 $1,335 $0 $1,335
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 11/09/2007 12/14/2007 $1,150 $1,150 $0 -  
2. 01002 Other 3668 A02 11/09/2007 12/14/2007 $185 $185 $0 -  

Investigation Summary

Investigation Nr: 202465159
Event: 07/26/2007
Employee Amputates Finger While Repairing Machine

The employer is a cosmetic manufacturer but manufactures no cosmetics at the facility. They manufacture plastic compact cases, lipstick cases and bottle for lotions and perfumes for their line. The process involved using plastic molding extrusion. The equipment used utilizes an oil hydraulic system to force the molten plastic into the mold and also to operate the extruder. There is a tank at the back and bottom of the machine that houses nitrogen gas. The gas is used to increase the hydraulic pressure. The tank has a rubber bag inside called a "bladder"; therefore the tank is known as a "bladder tank". Approximately once or twice per year, the bags develop a leak and have to be replaced. There is another tank above the bladder tank called an "evaporator tank". At the time of incident, Employee #1, the maintenance man, who has performed this repair and replacement procedure several times, was asked by the molding dept manager that a new employee was assigned to help him. Employee #1 told the manager that he didn't need anyone to help. The bladder tank was removed without incident. The new bladder was put in by Employee #1 at the maintenance shop and then brought back by forklift to the machine for installation. According to both Employee #1 and the witness, the tank was placed on the forks of the industrial truck and was prevented from rolling by bolts placed vertically on the forks. The tank was raised to the proper level but a wood 2-in. by 4-in. plank was placed between the bladder tank being raised and the evaporator tank that was permanently affixed to the machine. Employee #1 had placed a "U" bracket on both sides of the bladder tank. On the left side, as you are facing the tank, he was putting anchor bolts through the "u" bracket. Employee #1 had his left hand above the "U" bracket and his right hand below the "U" bracket between the bracket and the bladder tank. According to Employee #1, the 2-in. by 4-in. plank split in half causing the forks to raise enough to have his right hand crushed between the "U" bracket and the tank. Employee #1 had his middle, annular and pinky finger crushed which resulted in a partial amputation of all fingers involved. Employee #1 was hospitalized.

Keywords: MAINTENANCE, AMPUTATED, REPAIR, FINGER, CRUSHED, INDUSTRIAL TRUCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310198569 Hospitalized injury Amputation Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close