Powered by GoogleTranslate

Inspection Detail

Inspection: 310197819 - Senior Aerospace

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 310197819
Report ID: 0950643
Date Opened: 06/28/2007

Site Address:
Senior Aerospace
2980 N. San Fernando Blvd.
Burbank, CA 91504

Mailing Address:
, , 00000

Union Status: Union

SIC:3728

NAICS: 336413/Other Aircraft Parts and Auxiliary Equipment Manufacturing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/13/2007

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/12/2007


Related Activity
Type Activity Nr Safety Health
Accident 101119444

Investigation Summary

Investigation Nr: 202464988
Event: 06/14/2007
Employee Is Injured in Tank Explosion

At approximately 10:30 a.m. on June 14, 2007, Employee #1 was leak testing a 4 foot long, 4 inch diameter titanium duct tube by applying 420 psi air while the tube was in an enclosed water tank. Employee #1 released the air pressure after one minute and the pressure gage reading was at zero air pressure. Employee #1 then placed the titanium duct tube on the adjacent work bench and began removing the cover plugs from the ends of the titanium tube when it suddenly exploded. Two coworkers immediately came over to help Employee #1. The supervisor called the city fire paramedics when informed of the accident by the coworkers. Employee #1 was taken to Saint Joseph Hospital and was diagnosed with a right hand fractured thumb, lacerations to the stomach, and right wrist. Employee #1 was admitted to the hospital for three days. The coworkers did not observe the accident when it occurred. The employer was Senior Aerospace, a manufacturer of aircraft ducting.

Keywords: LEAK, AIR PRESSURE, ABDOMEN, DUCT, THUMB, EXPLOSION, WRIST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310197819 Hospitalized injury Fracture Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.