Inspection Detail
Inspection: 310141130 - Bridge Mark Heating & Cooling Services, Inc.
Inspection Information - Office: Va-E-Norfolk (Regional Office) - Safety 0355112
Site Address:
Bridge Mark Heating & Cooling Services, Inc.
551 Randolph Road Apt 2-B
Newport News, VA 23601
Mailing Address:
3303 Airline Blvd., Suite 4-B, Portsmouth, VA 23701
Union Status: NonUnion
SIC:7623
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/12/2006
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 04/03/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100922764 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 7 | 1 | 8 | |||
Current Violations | 5 | 1 | 6 | |||
Initial Penalty | $31,000 | $0 | $0 | $0 | $0 | $31,000 |
Current Penalty | $9,250 | $0 | $0 | $0 | $0 | $9,250 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100132 D01 | 12/13/2006 | 12/31/2006 | $750 | $750 | $0 | 12/29/2006 | Y - State Decision | |
2. | 01001B | Serious | 19100132 D02 | 12/13/2006 | 12/31/2006 | $0 | $0 | $0 | 12/29/2006 | Y - State Decision | |
3. | 01002 | Serious | 19100147 C01 | 12/13/2006 | 01/15/2007 | $750 | $750 | $0 | 12/29/2006 | Y - State Decision | |
4. | 01003 | Serious | 19100303 G02 I | 12/13/2006 | 12/23/2006 | $750 | $7,000 | $0 | 12/29/2006 | Y - State Decision | |
5. | 01004 | Serious | 19100333 A02 | 12/13/2006 | 12/23/2006 | $1,500 | $1,500 | $0 | 12/29/2006 | Y - State Decision | Citation has been deleted. |
6. | 01005 | Serious | 19100333 C07 | 12/13/2006 | 12/28/2006 | $7,000 | $7,000 | $0 | 12/29/2006 | Y - State Decision | Citation has been deleted. |
7. | 01006 | Serious | 19100335 A01 I | 12/13/2006 | 12/23/2006 | $7,000 | $7,000 | $0 | 12/29/2006 | Y - State Decision | Citation has been deleted. |
8. | 01007A | Serious | 19100335 A01 I | 12/13/2006 | 12/23/2006 | $3,500 | $0 | $0 | 12/29/2006 | Q - National Office Adjustment | |
9. | 01007B | Serious | 19100333 A02 | 12/13/2006 | 12/23/2006 | $0 | $0 | $0 | 12/29/2006 | Q - National Office Adjustment | |
10. | 01008 | Serious | 19100333 C07 | 12/13/2006 | 12/28/2006 | $3,500 | $7,000 | $0 | 12/29/2006 | Y - State Decision | |
11. | 02001 | Other | 19101200 E01 | 12/13/2006 | 12/31/2006 | $0 | $0 | $0 | 12/29/2006 | Y - State Decision |
Investigation Summary
On June 28, 2006, Employee #1, an HVAC mechanic, was repairing an air conditioner unit on a second floor apartment in a multi-family apartment building. He was working from an aluminum extension ladder. He had replaced the compressor when apartment residents heard a loud noise. They found Employee #1 lifeless, lying on the ground below the ladder, killed by electrocution.
Keywords: COMPRESSOR, UNCONSCIOUSNESS, REPAIR, AIR CONDITIONER, METAL LADDER, NOISE, ELECTRIC SHOCK, FALL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 310141130 | Fatality | Electric Shock | Heating, air conditioning, and refrig. mechanics |