Powered by GoogleTranslate

Inspection Detail

Inspection: 310100607 - Big 4 Corporation Dba Boulevard Cafe

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 310100607
Report ID: 0950613
Date Opened: 08/19/2011

Site Address:
Big 4 Corporation Dba Boulevard Cafe
2 Poncetta Drive
Daly City, CA 94015

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5812

NAICS: 722110/Full-Service Restaurants


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/19/2011

Emphasis:

Case Closed: 01/28/2012


Related Activity
Type Activity Nr Safety Health
Accident 101138154
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $2,925 $0 $0 $805 $0 $3,730
Current Penalty $2,925 $0 $0 $805 $0 $3,730
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 12/19/2011 01/21/2012 $160 $160 $0 -  
2. 01002 Other 3314 G 12/19/2011 01/21/2012 $160 $160 $0 -  
3. 01003 Other 5194 E01 12/19/2011 01/21/2012 $160 $160 $0 -  
4. 01004 Other 5162 A 12/19/2011 01/21/2012 $325 $325 $0 -  
5. 02001 Serious 3314 C 12/19/2011 01/21/2012 $2,925 $2,925 $0 -  

Investigation Summary

Investigation Nr: 201128428
Event: 08/13/2011
Employee's Fingers Are Injured When Caught in Grinder

At approximately 1:00 p.m. on August 13, 2011, Employee #1, with Boulevard Cafe Restaurant, was assembling a meat grinder in a food preparation area. The meat grinder consisted of a chute, a screw conveyor (worm), a blade, a plate, and a ring. When the grinder was partially assembled, she attempted to move it and inadvertently activated the power switch to "Rev" position. At this time, Employee #1 was holding the worm partially inserted into the chute. When the machine activated, the worm pulled her left index and middle fingers into the chute. Employee #1 was hospitalized at Seton Medical Center for finger fractures and lacerations. She stated that she did not see the grinder cord plugged into the outlet where it was usually plugged in and assumed it was unplugged. After the accident, the employer found that the grinder was plugged into an outlet located out of sight behind a blender.

Keywords: GRINDER, FRACTURE, SCREW CONVEYOR, FINGER, CAUGHT BY, LOCKOUT, LACERATION, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310100607 Hospitalized injury Cut/Laceration Kitchen workers, food preparation
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close