Powered by GoogleTranslate

Inspection Detail

Inspection: 310098884 - American Food Service

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 310098884
Report ID: 0950613
Date Opened: 11/17/2010

Site Address:
American Food Service
2991 Mead Avenue
Santa Clara, CA 95051

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5421

NAICS: 445210/Meat Markets


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/13/2010

Emphasis:

Case Closed: 01/18/2011


Related Activity
Type Activity Nr Safety Health
Accident 101136216
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $0 $0 $0 $250 $0 $250
Current Penalty $0 $0 $0 $250 $0 $250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 12/13/2010 01/05/2011 $125 $125 $0 -  
2. 01002 Other 3249 B 12/13/2010 01/05/2011 $0 $0 $0 -  
3. 01003 Other 3249 C 12/13/2010 01/05/2011 $0 $0 $0 -  
4. 01004 Other 3249 D 12/13/2010 01/05/2011 $125 $125 $0 -  
5. 01005 Other 5141 A 12/13/2010 01/05/2011 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201127933
Event: 11/17/2010
Nonemployee Is Exposed to Carbon Monoxide

At approximately 1:10 p.m. on November 17, 2010, a nonemployee, the ex-husband of a woman who was a friend of a red meat company owner, was power washing the inside of a freezer. The freezer's internal room had a 42 ft length by 52 ft width by 10.5 ft height. He was operating a Honda GXV 340 pressure washer (Serial Number A1410). The power washing machine was located outside the freezer, while the nonemployee was located inside the freezer. He would occasionally enter and exit the freezer to turn the washer's power off and on. After operating the pressure washer for approximately 20 minutes, he felt feint and started to collapse a few feet from the pressure washer. His ex-wife, who was approximately 40 ft away, saw him and she went to help. He staggered outside of the facility and was helped by his ex-wife and a company's employee. There was a concern of carbon monoxide gas in the area. The building was evacuated and emergency services were summoned. The fire department arrived and took air samples. The carbon monoxide readings of the air that surrounded the pressure washer were greater than 225 parts per million. Carbon monoxide has a permissible exposure level of 25 parts per million for an 8 hour period. Seven people went to the hospital and all were released within two to four hours. Of the seven people that went to the hospital, three were employees, two were employers and the last two were nonemployees.

Keywords: PORTABLE POWER TOOL, RESPIRATORY, CLEANING, INHALATION, FREEZER COMPARTMENT, OVEREXPOSURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310098884 Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.