Powered by GoogleTranslate

Inspection Detail

Inspection: 310054747 - Pacific Steel Casting Co

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 310054747
Report ID: 0950614
Date Opened: 06/30/2006

Site Address:
Pacific Steel Casting Co
1333 2nd St
Berkeley, CA 94710

Mailing Address:
, , 00000

Union Status: Union

SIC:3325

NAICS: 331513/Steel Foundries (except Investment)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/28/2006

Emphasis:

Case Closed: 09/09/2008


Related Activity
Type Activity Nr Safety Health
Accident 361631948
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $5,400 $0 $0 $0 $0 $5,400
Current Penalty $0 $0 $0 $600 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23200002 A05 08/02/2006 08/07/2006 $600 $5,400 $0 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201506615
Event: 06/23/2006
Employee Falls Off Ladder after Receiving an Electric Shock

At approximately 8:00 a.m. on June 23, 2006, Employee #1, a maintenance mechanic, received a red flag work order for a 1T overhead hoist. The pendant cord was stuck in one position and no one could get it down. Employee #1 took a 10-ft A-frame ladder and leaned it at a 45 degree angle against the wall. He instructed a maintenance helper to hold the ladder for him. Employee #1 climbed up the ladder, deenergized the hoist and proceeded to replace the pendant cord. After replacing the cord, he plugged the hoist back in and tested the operation. The high and low limit settings were not working properly, so Employee #1 began to make adjustments to the limit switches. The hoist had to be energized in order to set the limit settings. While in the process of making the adjustments, his left hand touched a 110-volt circuit wire, resulting in an electrical shock, and causing him to fall 6.67 feet backwards off the ladder. He fell onto the coworker, then onto a 3-ft tall air grinding tool stand. Employee #1 sustained five fractured ribs. He was transported to a nearby emergency room, where he remained for two days and then was transferred closer to his home. He was hospitalized there for another six days.

Keywords: FRACTURE, MAINTENANCE, LADDER, MECHANIC, STRUCK AGAINST, HOIST, RIB, ELECTRIC SHOCK, FALL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310054747 Hospitalized injury Fracture Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close