Powered by GoogleTranslate

Inspection Detail

Inspection: 310051263 - Builder Services Group, Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 310051263
Report ID: 0352410
Date Opened: 07/07/2006

Site Address:
Builder Services Group, Inc.
311 Whistling Swan Way
Queenstown, MD 21658

Mailing Address:
621 West Division Street, Dover, DE 19901

Union Status: NonUnion

SIC:1761

NAICS: 238390/Other Building Finishing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/17/2006

Planning Guide: Safety-Construction

Emphasis: S:Construction, S:Falls

Case Closed: 07/18/2006


Related Activity
Type Activity Nr Safety Health
Accident 102359478

Investigation Summary

Investigation Nr: 202362067
Event: 07/07/2006
Employee Is Injured in Fall from Sinking Ladder

On July 7, 2006, Employee #1 was installing gutters on the front of a newly constructed home. He was working from a 20-ft extension ladder. The ladder became unstable when one of the feet on the ladder sank into the ground. Employee #1 was injured when he and the ladder fell approximately 13 ft 9 in. to the concrete steps below. Employee #1 was hospitalized for four fractured ribs, a laceration to the right temple, a lacerated liver, and a fractured nasal cavity.

Keywords: FRACTURE, EXTENSION LADDER, CONSTRUCTION, LIVER, LACERATION, RIB, UNSTABLE SURFACE, FALL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310051263 Hospitalized injury Fracture Construction trades, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.