Powered by GoogleTranslate

Inspection Detail

Inspection: 309909422 - Pacific Toll Processing Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 309909422
Report ID: 0950635
Date Opened: 05/08/2008

Site Address:
Pacific Toll Processing Inc
24724 S Wilmington Ave
Carson, CA 90745

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3312

NAICS: 331111/Iron and Steel Mills


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/09/2008

Emphasis:

Case Closed: 04/08/2010


Related Activity
Type Activity Nr Safety Health
Accident 362465007
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 2 3
Initial Penalty $25,420 $0 $0 $0 $0 $25,420
Current Penalty $3,710 $0 $0 $545 $0 $4,255
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23200002 A 09/09/2008 09/12/2008 $410 $18,000 $0 F - Formal Settlement  
2. 02001 Other 23200001 A 09/09/2008 09/12/2008 $135 $3,710 $0 F - Formal Settlement  
3. 03001 Serious 3314 F 09/09/2008 09/12/2008 $3,710 $3,710 $0 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202528733
Event: 04/24/2008
Employee Is Burned While Inserting Fuse

At approximately 12:30 p.m. on April 24, 2008, Employee #1, a mechanic, and his coworker were called to service a slitter machine making a loud noise at a steel processing company in Carson, CA. Employee #1 and his coworker arrived at the slitter machine and removed the cover plates to the drive motor. They discovered that the gearbox for the head drive motor had a cracked casing. After discovering the cracked casing, Employee #1 deenergized the slitting head drive motor by placing the slitting machine motor control center disconnect switch into the "OFF" position. Employee #1 and his coworker then began to disassemble and remove the gear box. As Employee #1 and his coworker worked on the cracked gear box casing, someone from the slitter machine banding line requested power to their area, so that they could complete their work. Upon the request to return power to the banding line, Employee #1 returned to the slitting machine motor control center and turned the power back on by moving the control center disconnect switch into the "ON" position. After returning the power to the slitter machine banding line, Employee #1 returned to the slitting head drive motor gear box and noticed the head drive motors cooling fan running. Therefore, Employee #1 returned to the motor control center to discontinue electrical power to the fan by using approved fiberglass fuse pliers to pull a 10-amp fuse from the motor control center. After removing the 10-amp fuse, Employee #1 returned to the cracked gear box and noticed that the cooling fan was still running. He concluded that he had pulled the wrong fuse and returned to the slitter machine motor control center. As Employee #1 was using the approved fuse pliers in his left hand to replace the 10-amp fuse he had removed, an electrical arc occurred and burned his face and left arm. Company supervisors responded to a popping sound in the area and took Employee #1 to the company clinic. From the clinic, Employee #1 was transported to Long Beach Memorial Medical Center. He was hospitalized for treatment, which included skin grafts for first and second degree burns to his left arm and face.

Keywords: BURN, FUSE, ELECTRIC ARC, LOCKOUT, ARM, FACE, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309909422 Hospitalized injury Burn/Scald(Heat) Not specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close