Inspection Detail
Inspection: 309906436 - Spg Solar
Inspection Information - Office: Long Beach District Office
Site Address:
Spg Solar
Cal State Long Beach 1250 Bellflower
Long Beach, CA 90840
Mailing Address:
863 E Francisco Blvd Suite A, San Rafael, CA 94901
Union Status: NonUnion
SIC:1711
NAICS: 238210/Electrical Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/14/2007
Emphasis:
Case Closed: 07/11/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362434532 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $0 | $0 | $0 | $5,000 | $0 | $5,000 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 11/14/2007 | 11/19/2007 | $0 | $5,000 | $0 | 12/11/2007 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At approximately 1:00 P.m. on May 17, 2007, Employee #1, a solar panel installer, was checking the battery of a power tool while working on a roof. A gust of wind blew a photovoltaic panel which hit his left Achilles tendon. He suffered a laceration, 1-in. wide by 3-in. long, to the Achilles tendon and was hospitalized.
Keywords: HIGH WIND, ROOF, LACERATION, STRUCK BY, FLYING OBJECT, FOOT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309906436 | Hospitalized injury | Cut/Laceration | Occupation not reported |
Translate