Powered by GoogleTranslate

Inspection Detail

Inspection: 309806313 - Smith & Keene Electric Services, Inc.

Inspection Information - Office: Va-E-Norfolk (Regional Office) - Safety 0355112

 

Inspection Nr: 309806313
Report ID: 0355112
Date Opened: 02/15/2006

Site Address:
Smith & Keene Electric Services, Inc.
9909 West Cork Road
Toano, VA 23168

Mailing Address:
833 Live Oak Drive, Chesapeake, VA 23320

Union Status: NonUnion

SIC:1711

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/15/2006

Planning Guide: Safety-Construction

Emphasis: N:Trench, S:Construction Fatalities

Case Closed: 09/06/2006


Related Activity
Type Activity Nr Safety Health
Accident 100922624
Referral 202445367 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 2 8
Current Violations 5 1 6
Initial Penalty $18,875 $140,000 $0 $750 $0 $159,625
Current Penalty $28,250 $0 $0 $0 $0 $28,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 06/22/2006 07/02/2006 $3,500 $7,000 $0 07/11/2006 Y - State Decision  
2. 01002 Serious 19260050 C 06/22/2006 07/25/2006 $1,125 $1,125 $0 07/11/2006 Y - State Decision Citation has been deleted.
3. 01003 Serious 19260651 C02 06/22/2006 07/02/2006 $3,750 $3,750 $0 07/11/2006 Y - State Decision  
4. 01004 Serious 19260651 J02 06/22/2006 07/02/2006 $7,000 $7,000 $0 07/11/2006 Y - State Decision  
5. 02001 Serious 19260651 K01 06/22/2006 07/02/2006 $7,000 $70,000 $0 07/11/2006 Y - State Decision  
6. 02002 Serious 19260652 A01 06/22/2006 07/02/2006 $7,000 $70,000 $0 07/11/2006 Y - State Decision  
7. 03001 Other 19040032 B06 06/22/2006 06/27/2006 $750 $750 $0 07/11/2006 Y - State Decision Citation has been deleted.
8. 03002 Other CSAN0051 C01 06/22/2006 07/07/2006 $0 $0 $0 07/11/2006 Y - State Decision  

Investigation Summary

Investigation Nr: 200924306
Event: 02/15/2006
Employee killed when trench wall caves in

On February 15, 2006, Employee #1 was installing a sanitary sewer house connection in an approximately 7 ft deep trench. A section of trench wall broke loose and fell on top of him. Employee #1 was killed.

Keywords: EXCAVATION, INSTALLING, WORK RULES, CONSTRUCTION, TRENCH, STRUCK BY, CAVE-IN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309806313 Fatality Other Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.