Inspection Detail
Inspection: 309768257 - Radyne Corporation
Inspection Information - Office: Naperville Area Office
Site Address:
Radyne Corporation
1000 Park Ave.
Sycamore, IL 60178
Mailing Address:
211 W. Boden Street, Milwaukee, IL 53207
Union Status: NonUnion
SIC:3567
NAICS: 333994/Industrial Process Furnace and Oven Manufacturing
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/08/2007
Emphasis:
Case Closed: 03/22/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 205838824 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
| Current Penalty | $1,250 | $0 | $0 | $0 | $0 | $1,250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100147 C04 II | 02/12/2007 | 03/16/2007 | $1,250 | $2,500 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100147 C07 I | 02/12/2007 | 03/16/2007 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 3. | 01001C | Serious | 19100147 F02 I | 02/12/2007 | 03/16/2007 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 4. | 02001 | Other | 19040031 A | 02/12/2007 | 03/02/2007 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
On August 14, 2006, Employee #1, an outside contractor, was servicing a heat induction machine. He had the door to the power supply cabinet open and was standing on a two-step aluminum ladder, while leaning into the cabinet to attach leads from a multimeter to live electrical components. While reaching into the cabinet, he contacted the high-voltage resistor with his left shoulder and received a severe shock and burn injuries. Employee #1 was hospitalized. The investigation revealed that Employee #1 did not deenergize and lockout the machine before attaching the multimeter leads to the live components. He was not wearing or using electrical protective equipment, such as dielectric gloves, blankets, or barriers to prevent contact with the live electrical components. Employee #1 was also not protected by distance. The machine's voltage varied between 230 volts and 11,000 volts. A maintenance employee of the host employer was working in the area at the time of the accident, but was not working directly with Employee #1. Employee #1 was new at the position and had only serviced the heat induction machine at the host employer location one other time. The employer did not have specific procedures for employees to follow for the deenergization and lockout of equipment at customer sites. The investigation concluded that inadequate training and experience contributed to the accident.
Keywords: BURN, SHOULDER, PPE, HEATER, LOCKOUT, INEXPERIENCE, METAL LADDER, ELECTRIC SHOCK, ELECTRICAL CABINET, UNTRAINED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309768257 | Hospitalized injury | Electric Shock | Industrial machinery repairers |