Powered by GoogleTranslate

Inspection Detail

Inspection: 309760726 - Ace Landscapes, Inc.

Inspection Information - Office: Austin Area Office

 

Inspection Nr: 309760726
Report ID: 0625400
Date Opened: 08/01/2007

Site Address:
Ace Landscapes, Inc.
1735 Westmeadow
Round Rock, TX 78664

Mailing Address:
104 S. Fm 1660, Hutto, TX 78634

Union Status: NonUnion

SIC:0782

NAICS: 561730/Landscaping Services


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/01/2007

Emphasis:

Case Closed: 12/04/2007


Related Activity
Type Activity Nr Safety Health
Accident 100604313
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $7,500 $0 $0 $1,250 $0 $8,750
Current Penalty $4,500 $0 $0 $1,250 $0 $5,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260404 B01 I 09/19/2007 09/25/2007 $2,000 $2,500 $0 I - Informal Settlement  
2. 01002 Serious 19260404 F06 09/19/2007 09/25/2007 $1,250 $2,500 $0 I - Informal Settlement  
3. 01003 Serious 19260405 G02 III 09/19/2007 09/25/2007 $1,250 $2,500 $0 I - Informal Settlement  
4. 01004A Other 19260020 B01 09/19/2007 10/30/2007 $1,250 $1,250 $0 I - Informal Settlement  
5. 01004B Other 19260059 E01 09/19/2007 10/30/2007 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200603710
Event: 07/31/2007
Employee Is Electrocuted by Extension Cord

On July 31, 2007, Employee #1 was drilling a hole in the wall of the residence, to install a lawn sprinkler system. He was using an extension cord which did not have a grounding pin. The extension cord had been spliced at different locations and was wired wrong. Employee #1 was electrocuted by the extension cord.

Keywords: SHOCK, CORD SET, ELECTROCUTED, ELECTRIC SHOCK, ELECTRICAL SPLICE, GROUNDING ELECTRODE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309760726 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close