Inspection: 309704443 - Summit Fire Protection
Inspection Information - Office: Kansas City Area Office
Site Address:
Summit Fire Protection
1206 West Fairview
Carthage, MO 64836
Mailing Address:
7301 Apollo, Lino Lakes, MN 55014
Union Status: Union
SIC:1799
NAICS: 238990/All Other Specialty Trade Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/28/2006
Planning Guide: Safety-Construction
Emphasis: L:Xfallelec, S:Construction Fatalities
Case Closed: 04/06/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100003045 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 1 | 5 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $14,850 | $63,000 | $0 | $0 | $0 | $77,850 |
| Current Penalty | $0 | $50,000 | $0 | $0 | $0 | $50,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260502 D11 | 08/09/2006 | 08/28/2006 | $0 | $4,500 | $0 | 08/31/2006 | F - Formal Settlement | Citation has been deleted. |
| 2. | 01002 | Serious | 19260502 D15 | 08/09/2006 | 08/28/2006 | $0 | $4,500 | $0 | 08/31/2006 | F - Formal Settlement | Citation has been deleted. |
| 3. | 01003 | Serious | 19260502 D21 | 08/09/2006 | 08/28/2006 | $0 | $1,350 | $0 | 08/31/2006 | F - Formal Settlement | Citation has been deleted. |
| 4. | 01004 | Serious | 19261053 B04 | 08/09/2006 | 08/28/2006 | $0 | $4,500 | $0 | 08/31/2006 | F - Formal Settlement | Citation has been deleted. |
| 5. | 02001 | Willful | 19260501 B01 | 08/09/2006 | 08/28/2006 | $50,000 | $63,000 | $0 | 08/31/2006 | F - Formal Settlement |
Investigation Summary
On March 29, 2006, Employee #1 was installing a sprinkler system for fire protection. He was climbing up on a stationary rack on his way to install the sprinkler system on the twelfth level of a structure, approximately 60 feet above the ground. He was wearing fall protection, but he was not provided with anchorage points for tying off. He was using a 10-foot modified ladder to reach each walking and working surface. When he reached the first level, approximately 15 feet above the ground, he fell. He sustained a concussion, and he was killed.
Keywords: PPE, CONSTRUCTION, FALL, FALL PROTECTION, CONCUSSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309704443 | Fatality | Concussion | Occupation not reported |