Powered by GoogleTranslate

Inspection Detail

Inspection: 309555811 - Bradley Jackson Contracting

Inspection Information - Office: Concord Area Office

 

Inspection Nr: 309555811
Report ID: 0111700
Date Opened: 02/27/2007

Site Address:
Bradley Jackson Contracting
Pinecrest Road
Jaffrey, NH 03452

Mailing Address:
P.O. Box 632, Jaffrey, NH 03452

Union Status: NonUnion

SIC:1521

NAICS: 236115/New Single-Family Housing Construction (except Operative Builders)


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/28/2007

Emphasis: S:Residential Constr

Case Closed: 08/28/2007


Related Activity
Type Activity Nr Safety Health
Referral 200618320 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $3,300 $0 $0 $0 $0 $3,300
Current Penalty $3,300 $0 $0 $0 $0 $3,300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B05 07/31/2007 08/24/2007 $1,500 $1,500 $0 -  
2. 01001B Serious 19260021 B06 I 07/31/2007 08/24/2007 $0 $0 $0 -  
3. 01002 Serious 19261053 B01 07/31/2007 08/24/2007 $600 $600 $0 -  
4. 01003 Serious 19261053 B05 I 07/31/2007 08/24/2007 $600 $600 $0 -  
5. 01004 Serious 19261060 A 07/31/2007 08/24/2007 $600 $600 $0 -  

Investigation Summary

Investigation Nr: 200612596
Event: 02/27/2007
Construction Laborer Is Burned When Propane Vapors Ignite

On February 27, 2007, Employee #1 was working for a contractor as a construction laborer in the basement of a house that was being built. A disabled safety mechanism on a Reddy Heater brand propane-fueled space heater caused unburned propane gas to collect in the basement. When Employee #1 attempted to light the heater, the accumulated gas burst into flame. Employee #1 sustained burns over several parts of his body. He was hospitalized.

Keywords: BURN, FLAMMABLE VAPORS, INADEQUATE MAINT, HEATER, CONSTRUCTION, PROPANE, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309555811 Hospitalized injury Burn/Scald(Heat) Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.