Inspection Detail
Inspection: 309519585 - Fernando Hernandez Dba Chacalapa Installations
Inspection Information - Office: Nc Department Of Labor - Winston-Salem
Site Address:
Fernando Hernandez Dba Chacalapa Installations
1135 Lawson'S Garage Rd
Westfield, NC 27053
Mailing Address:
433 Herring St., Mount Airy, NC 27030
Union Status: NonUnion
SIC:1799
NAICS: 238990/All Other Specialty Trade Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/19/2006
Planning Guide: Safety-Construction
Emphasis: S:Program Improvements
Case Closed: 12/07/2007
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100073295 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 2 | 6 | |||
Current Violations | 4 | 2 | 6 | |||
Initial Penalty | $4,950 | $0 | $0 | $1,500 | $0 | $6,450 |
Current Penalty | $3,300 | $0 | $0 | $1,000 | $0 | $4,300 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19260404 B01 I | 10/20/2006 | 10/25/2006 | $700 | $1,050 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19260404 F06 | 10/20/2006 | 10/25/2006 | $0 | $0 | $0 | - | ||
3. | 01001C | Serious | 19260416 E01 | 10/20/2006 | 10/25/2006 | $0 | $0 | $0 | - | ||
4. | 01001D | Serious | 19260020 B02 | 10/20/2006 | 10/25/2006 | $0 | $0 | $0 | - | ||
5. | 01001E | Serious | 19260021 B02 | 10/20/2006 | 10/25/2006 | $0 | $0 | $0 | - | ||
6. | 01002A | Serious | 19260416 A01 | 10/20/2006 | 10/25/2006 | $1,400 | $2,100 | $0 | I - Informal Settlement | ||
7. | 01002B | Serious | 19260416 A03 | 10/20/2006 | 10/25/2006 | $0 | $0 | $0 | - | ||
8. | 01003A | Serious | 19260501 B01 | 10/20/2006 | 10/25/2006 | $700 | $1,050 | $0 | I - Informal Settlement | ||
9. | 01003B | Serious | 19260503 A01 | 10/20/2006 | 11/16/2006 | $0 | $0 | $0 | - | ||
10. | 01004A | Serious | 19261053 B13 | 10/20/2006 | 10/25/2006 | $500 | $750 | $0 | I - Informal Settlement | ||
11. | 01004B | Serious | 19261060 A | 10/20/2006 | 11/16/2006 | $0 | $0 | $0 | - | ||
12. | 02001 | Other | 19040039 A | 10/20/2006 | 10/25/2006 | $1,000 | $1,500 | $0 | I - Informal Settlement | ||
13. | 02002 | Other | 19261053 B16 | 10/20/2006 | 10/25/2006 | $0 | $0 | $0 | - |
Investigation Summary
On August 26, 2006, Employee #1 and a coworker were erecting a 24 ft by 40 ft aluminum building in Westfield, NC. Employee #1 was walking along the top plate of the building, installing structural supports. His coworker handed him an approximately 6 in. wide by 20 ft long piece of head channel to install as part of the structural roof support. Employee #1 was putting the head channel in place when it contacted an overhead power line. He sustained an electric shock that knocked him 13 ft 9 in. to the next lower level. Employee #1 was electrocuted but he sustained secondary internal injuries in the fall.
Keywords: ERECTION PROCESS, CLEARANCE, INSTALLING, OVERHEAD POWER LINE, ELECTRICAL, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, FALL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 309519585 | Fatality | Electric Shock | Occupation not reported |