Powered by GoogleTranslate

Inspection Detail

Inspection: 309507234 - Black & Decker (U.S.) Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 309507234
Report ID: 0352450
Date Opened: 01/02/2007

Site Address:
Black & Decker (U.S.) Inc.
626 Hanover Pike
Hampstead, MD 21074

Mailing Address:
701 East Joppa Road, Towson, MD 21286

Union Status: NonUnion

SIC:3364

NAICS: 332721/Precision Turned Product Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/22/2007

Planning Guide: Safety-Manufacturing

Emphasis: S:Amputations

Case Closed: 03/06/2007


Related Activity
Type Activity Nr Safety Health
Accident 102360260
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,850 $0 $0 $0 $0 $3,850
Current Penalty $3,850 $0 $0 $0 $0 $3,850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A05 02/19/2007 02/23/2007 $3,850 $3,850 $0 -  

Investigation Summary

Investigation Nr: 202347738
Event: 12/13/2006
Employee Is Injured While Working in Powder Metal Plant

On December 13, 2006, Employee #1 was operating a box temper furnace in the heat treatment section of a plant dealing with powdered metals. Part of the heat treatment process includes a cooling table were the parts are cooled for approximately 1.5 hours. While Employee #1 was standing on the side of the cooling table with the furnace to his left side, he noticed that an inspection tag fell from a clip that was attached to the front of the table. The tag was sucked up into the bottom of the table. Employee #1 attempted to reach under the table to retrieve the tag, placing his left hand and arm into the path of an unguarded rotating fan blade that was mounted underneath the table. The fan was mounted about 38.75 inches above the floor. As he reached for the tag, Employee #1's hand came into contact with the fan blade. He was transported to Union Memorial Hospital Hand Trauma Center, where he was hospitalized and treated for four broken fingers, a broken wrist, broken Ulna or Radius, and lacerated middle finger. The accident investigation revealed that Employee #1 was unaware that the fan was not guarded.

Keywords: FRACTURE, PPE, EQUIPMENT OPERATOR, CAUGHT BY, LACERATION, STRUCK BY, HAND, UNGUARDED, BLIND REACHING, WRIST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309507234 Hospitalized injury Fracture Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close