Inspection Detail
Inspection: 309442424 - Pandora Manufacturing Llc
Inspection Information - Office: Toledo Area Office
Site Address:
Pandora Manufacturing Llc
501 S. Basinger Rd.
Pandora, OH 45877
Mailing Address:
, , 00000
Union Status: Union
SIC:2869
NAICS: 325998/All Other Miscellaneous Chemical Product and Preparation Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/18/2006
Emphasis:
Case Closed: 10/27/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 202098786 | Yes | |
Referral | 202098869 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 13 | 1 | 1 | 15 | ||
Current Violations | 13 | 1 | 1 | 15 | ||
Initial Penalty | $30,600 | $56,000 | $2,400 | $0 | $0 | $89,000 |
Current Penalty | $10,000 | $7,000 | $1,920 | $0 | $0 | $18,920 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 C02 IV | 11/20/2006 | 01/09/2007 | $1,000 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
2. | 01002 | Serious | 19100106 C03 | 11/20/2006 | 12/01/2006 | $500 | $1,500 | $0 | 12/12/2006 | F - Formal Settlement | |
3. | 01003 | Serious | 19100106 C07 | 11/20/2006 | 01/09/2007 | $1,000 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
4. | 01004 | Serious | 19100106 E02 IVD | 11/20/2006 | 12/08/2006 | $500 | $1,200 | $0 | 12/12/2006 | F - Formal Settlement | |
5. | 01005 | Serious | 19100106 E03 III | 11/20/2006 | 01/09/2007 | $1,000 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
6. | 01006 | Serious | 19100106 E03 IVA | 11/20/2006 | 01/09/2007 | $1,000 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
7. | 01007 | Serious | 19100106 E05 IV | 11/20/2006 | 01/09/2007 | $1,000 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
8. | 01008 | Serious | 19100106 E05 V | 11/20/2006 | 01/09/2007 | $500 | $1,500 | $0 | 12/12/2006 | F - Formal Settlement | |
9. | 01009 | Serious | 19100106 E06 I | 11/20/2006 | 11/24/2006 | $1,000 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
10. | 01010 | Serious | 19100106 E09 I | 11/20/2006 | 12/01/2006 | $1,000 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
11. | 01011 | Serious | 19100133 A01 | 11/20/2006 | 12/01/2006 | $500 | $1,200 | $0 | 12/12/2006 | F - Formal Settlement | |
12. | 01012 | Serious | 19100178 C02 IV | 11/20/2006 | 01/09/2007 | $500 | $3,000 | $0 | 12/12/2006 | F - Formal Settlement | |
13. | 01013 | Serious | 19100303 B02 | 11/20/2006 | 12/08/2006 | $500 | $1,200 | $0 | 12/12/2006 | F - Formal Settlement | |
14. | 02001 | Willful | 19100307 B | 11/20/2006 | 12/08/2006 | $7,000 | $56,000 | $0 | 12/12/2006 | F - Formal Settlement | |
15. | 03001 | Repeat | 19100022 A01 | 11/20/2006 | 12/01/2006 | $1,920 | $2,400 | $0 | 12/12/2006 | F - Formal Settlement |
Investigation Summary
At approximately 7:40 a.m. on June 2, 2006, Employees #1 through #7 were working at Pandora Manufacturing, LLC, a company that blends bulk chemicals and then bottles and packages them to customer specifications. Three maintenance employees were attempting to reset the timing on a Consolidated capping machine that had malfunctioned, causing several 16 oz. bottles filled with a Class IB flammable liquid (an octane booster and fuel injection cleaner containing methanol, tertiary butanol, methyl tertiary butyl ether, AFD-25, and isopar E) to spill their contents. The contents were spilled directly on, in, and around the capping machine. When an employee attempted to turn on the machine, the spilled liquid ignited. All seven employees sustained burns, and some sustained smoke inhalation. Three of them were hospitalized for treatment. An investigation revealed that the electric service, including motors, relays, panel boxes, junctions, and outlets, were not rated for a Class 1 Division 1 locations.
Keywords: BURN, ELECTRIC MOTOR, RESPIRATORY, MAINTENANCE, FLAMMABLE LIQUID, FIRE, EQUIPMENT FAILURE, SMOKE INHALATION, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 309442424 | Hospitalized injury | Burn/Scald(Heat) | Machinery maintenance occupations | ||
2 | 309442424 | Non Hospitalized injury | Burn/Scald(Heat) | Machinery maintenance occupations | ||
3 | 309442424 | Non Hospitalized injury | Burn/Scald(Heat) | Chemical technicians | ||
4 | 309442424 | Non Hospitalized injury | Burn/Scald(Heat) | Machinery maintenance occupations | ||
5 | 309442424 | Hospitalized injury | Burn/Scald(Heat) | Managers and administrators, n.e.c | ||
6 | 309442424 | Hospitalized injury | Burn/Scald(Heat) | Managers and administrators, n.e.c | ||
7 | 309442424 | Non Hospitalized injury | Burn/Scald(Heat) | Managers and administrators, n.e.c |