Inspection Detail
Inspection: 309421394 - Operations Management International Inc
Inspection Information - Office: Eugene
Site Address:
Operations Management International Inc
Monroe Public Works 664 Commercial St
Monroe, OR 97456
Mailing Address:
National Registered Agents Inc, Salem, OR 97302
Union Status: NonUnion
SIC:4952
NAICS: 221320/Sewage Treatment Facilities
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/18/2006
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/27/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 201203189 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $250 | $0 | $250 |
| Current Penalty | $0 | $0 | $0 | $250 | $0 | $250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 701070021 C | 05/31/2006 | 06/05/2006 | $250 | $250 | $0 | - |
Investigation Summary
On March 14, 2006, Employee #1 was using an oxyacetylene torch to heat the metal pipe of a bent stop sign post so that he could straighten it. After reaching over the heated pipe to pick up a wrench that he was going to attach to the pipe for leverage, he noticed that the left side of his shirt was on fire. He proceeded approximately 50 feet to an outside water hose, which he used to douse himself. He then went next door to the Monroe Fire Department to seek medical assistance. He was hospitalized for his burns.
Keywords: BURN, ACETYLENE TORCH, METAL POLE, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309421394 | Hospitalized injury | Burn/Scald(Heat) | Miscellaneous plant and system operators |