Inspection Detail
Inspection: 309383115 - Mark Pierson Dba Port Bay Caretaking
Inspection Information - Office: Syracuse Area Office
Site Address:
Mark Pierson Dba Port Bay Caretaking
6467 Bonnie Castle Road
Wolcott, NY 14590
Mailing Address:
8330 Graves Point Rd., Wolcott, NY 14590
Union Status: NonUnion
SIC:1799
NAICS: 561790/Other Services to Buildings and Dwellings
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/24/2006
Emphasis:
Case Closed: 10/30/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100881820 |
Investigation Summary
On July 17, 2006, Employee #1 and a coworker-partner were replacing a cable on a boat hoist at a private residence. They were in the water, working with hand tools, when they both sustained electric shocks. The coworker managed to get out and then saw Employee #1 going under the surface. Thinking the situation was safe, the coworker went back in to help his partner, only to receive more shocks. Employee #1 was killed; the coworker sustained shock injuries, including damage to his heart. He also suffered from multiple infections, including in his lungs.
Keywords: HOISTING MECHANISM, WORK RULES, ELECTROCUTED, CONSTRUCTION, HOIST, ELEC CIRC PART--MISC, HAND TOOL, WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309383115 | Fatality | Electric Shock | Construction laborers |
Translate