Site Address:
Richard And Cathy Cheski
34036 Amber Lantern
Dana Piont, CA 92629
Mailing Address:
2840 Calle Esteban, San Clemente, CA 92673
Union Status: NonUnion
SIC:6531
NAICS: 531311/Residential Property Managers
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/16/2007
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/15/2007
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102525623 |
Investigation Summary
On June 4, 2007, Employee #1 was repairing a portion of irrigation piping, which required him to enter a crawl space underneath a house. As he was accessing the crawl space, he contacted bare wiring with the metal irrigation piping and was electrocuted. Employee #1 was killed. The accident investigation determined that the combination of the damp conditions and the metal irrigation piping contacting the exposed wiring caused the accident. However, no citations were issued due to a lack of employer-employee relationship, which made it difficult to determine jurisdictional responsibility.
Keywords: REPAIR, ELECTRIC CABLE, ELECTROCUTED, IRRIGATION PIPE, MANUAL MAT HANDLING, PIPE, METAL PIPE, WORK SURFACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|