Inspection Detail
Inspection: 309297364 - Bodycote Thermal Processing
Inspection Information - Office: Santa Ana District Office
Site Address:
Bodycote Thermal Processing
7474 Garden Grove Blv
Westminster, CA 92683
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3334
NAICS: 331312/Primary Aluminum Production
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/05/2007
Emphasis:
Case Closed: 11/20/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102485273 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $300 | $0 | $300 |
| Current Penalty | $0 | $0 | $0 | $300 | $0 | $300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3328 C | 06/05/2007 | 06/08/2007 | $300 | $300 | $0 | - |
Investigation Summary
At approximately 2:00 p.m. on December 5, 2006, Employee #1 was standing on a plywood platform making adjustments to the overhead louvers of a Alumatherm thermal heat treatment oven (Model Number 12, Serial Number DWG NO 3705-12) when the platform gave way causing Employee #1 to fall 9 ft 6 in., into the empty quenching sump floor. Employee #1 suffered a retroperitoneal hematoma and multiple rib fractures on the left side. Employee #1 was hospitalized.
Keywords: PLATFORM, FRACTURE, MAINTENANCE, RIB, UNSTABLE SURFACE, FALL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309297364 | Hospitalized injury | Other | Machinery maintenance occupations |
Translate