Inspection Detail
Inspection: 309296309 - Tac West Inc
Inspection Information - Office: Santa Ana District Office
Site Address:
Tac West Inc
1160 N Fee Ana Street
Anaheim, CA 92807
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7542
NAICS: 811192/Car Washes
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 10/30/2006
Emphasis:
Case Closed: 04/06/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102477379 |
Investigation Summary
On April 20, 2006, Employee #1 was using a high pressure hose, 130 to 150 psi, ALFAGOMMA, Model Number T33OAH-Red Cover, 0.75 in., with a RUB, Stainless Steel Ball Valve, Model Number 130F41, hose. He was removing material from the exterior of a food tanker located in a wash bay, using a 200 degrees F, soap, Type 15, Chemco 35, Sodium Tripolyphoshpate, mixed in solution with water. Employee #1 was injured when the hose ruptured above the nozzle clamp, and he was sprayed with the hot soap and water solution. He was wearing a hard hat, safety glasses, coveralls, hairnet, gloves, steel-toed rubber boots and a safety harness. Employee #1 suffered first and second degree burns to the right side of the chest, abdomen, right upper arm and thigh. Employee #1 was treated at a health care clinic then hospitalized for treatment of his burns.
Keywords: BURN, CLEANING, FOOD PACKAGING MACH, HOSE, HIGH PRESSURE, HIGH TEMPERATURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309296309 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |