Inspection Detail
Inspection: 309200590 - Revere Smelting & Refining Corp.
Inspection Information - Office: Albany Area Office
Site Address:
Revere Smelting & Refining Corp.
65 Ballard Road
Middletown, NY 10941
Mailing Address:
, , 00000
Union Status: Union
SIC:3341
NAICS: 331492/ Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum)
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/17/2005
Emphasis:
Case Closed: 11/24/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100741537 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $5,000 | $70,000 | $0 | $0 | $0 | $75,000 |
| Current Penalty | $5,000 | $0 | $0 | $0 | $70,000 | $75,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100179 G01 V | 02/06/2006 | 02/16/2006 | $2,500 | $2,500 | $0 | - | ||
| 2. | 01002 | Serious | 19100305 J04 IID | 02/06/2006 | 02/09/2006 | $2,500 | $2,500 | $0 | - | ||
| 3. | 02001 | Unclass | 5A0001 | 02/06/2006 | 02/16/2006 | $70,000 | $70,000 | $0 | 02/14/2006 | J - ALJ Decision |
Investigation Summary
On August 17, 2005, Employee #1 sustained severe burns while he was skimming dross from a vat of 850 degree molten lead. He died as a result of his injuries.
Keywords: BURN, MOLTEN METAL, REFINERY
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309200590 | Fatality | Burn/Scald(Heat) | Occupation not reported |