Powered by GoogleTranslate

Inspection Detail

Inspection: 309179117 - Brocks Welding

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 309179117
Report ID: 0522500
Date Opened: 09/29/2005

Site Address:
Brocks Welding
4900 Boggs Road
Zanesville, OH 43702

Mailing Address:
3985 E. Pike, Zanesville, OH 43702

Union Status: NonUnion

SIC:7692

NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/04/2005

Emphasis:

Case Closed: 06/23/2006


Related Activity
Type Activity Nr Safety Health
Accident 100752328
Referral 200752020 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $8,500 $0 $0 $0 $0 $8,500
Current Penalty $4,250 $0 $0 $0 $0 $4,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100252 A03 I 10/18/2005 10/28/2005 $1,000 $2,000 $0 I - Informal Settlement  
2. 01002 Serious 19100106 E06 I 10/18/2005 12/01/2005 $1,000 $2,000 $0 I - Informal Settlement  
3. 01003 Serious 19101200 E01 10/18/2005 10/28/2005 $750 $1,500 $0 I - Informal Settlement  
4. 01004 Serious 19101200 G01 10/18/2005 10/28/2005 $750 $1,500 $0 I - Informal Settlement  
5. 01005 Serious 19101200 H02 IV 10/18/2005 12/01/2005 $750 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200758126
Event: 09/28/2005
Employee Is Killed When Burned in Explosion

At approximately 10:00 a.m. on September 28, 2005, Employee #1 was welding a handle on the side of a crude oil storage tank at an oil drilling site. Prior to welding, Employee #1 hooked the exhaust from an internal combustion engine up to the tank to purge the flammable vapors, but didn't leave it running long enough to completely empty the tank. Also, the crude oil inside the tank was not cleaned out. The flammable natural gas inside the tank ignited and exploded, burning and killing Employee #1.

Keywords: BURN, FLAMMABLE VAPORS, FIRE, WELDER, NATURAL GAS, STORAGE TANK, EXPLOSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309179117 Fatality Burn/Scald(Heat) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close