Inspection Detail
Inspection: 309049237 - Harris Sales & Service, Inc.
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Harris Sales & Service, Inc.
20 A. L. Corbitt Circle
Wagener, SC 29164
Mailing Address:
Po Box 4286, West Columbia, SC 29170
Union Status: NonUnion
SIC:1711
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/03/2005
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 12/30/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100376201 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $1,750 | $0 | $1,750 |
| Current Penalty | $0 | $0 | $0 | $700 | $0 | $700 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 30039 | 10/18/2005 | 10/24/2005 | $700 | $1,750 | $0 | I - Informal Settlement |
Investigation Summary
On September 5, 2005, Employee #1 was troubleshooting an HVAC system at a job site. He had been trying to find the problem with the unit for approximately five minutes when he contacted live exposed conductors and was electrocuted. Employee #1 had been thoroughly trained on how to service this equipment.
Keywords: REPAIR, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, ELECTRICAL WORK, ELEC CIRC PART--MISC, ELECTRIC CONDUCTOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309049237 | Fatality | Electric Shock | Misc. electrical & electronic equipment repairers |
Translate