Powered by GoogleTranslate

Inspection Detail

Inspection: 309007938 - Commodities Unlimited Inc

Inspection Information - Office: Dosh Tumwater Service Location, Tumwater, Wa

 

Inspection Nr: 309007938
Report ID: 1055340
Date Opened: 06/01/2005

Site Address:
Commodities Unlimited Inc
7320 Bonniewood Dr
Tumwater, WA 98501

Mailing Address:
4206 77th Ave Se, Olympia, WA 98501

Union Status: NonUnion

SIC:4212

NAICS: 484110/ General Freight Trucking, Local


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/23/2005

Emphasis: L:Wasafety

Case Closed: 08/08/2006


Related Activity
Type Activity Nr Safety Health
Accident 101198398
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 1 3 4
Initial Penalty $1,400 $0 $0 $0 $0 $1,400
Current Penalty $100 $0 $0 $0 $0 $100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 80350005 10/18/2005 06/01/2005 $600 $600 $0 11/02/2005 L - State Settlement Citation has been deleted.
2. 01002 Other 80320005 10/18/2005 11/20/2005 $0 $200 $0 11/02/2005 L - State Settlement  
3. 01003 Serious 80014005 10/18/2005 11/20/2005 $100 $600 $0 11/02/2005 L - State Settlement  
4. 02001 Other 8001302502 10/18/2005 11/20/2005 $0 $0 $0 11/02/2005 L - State Settlement  
5. 02002 Other 1550061501 G 10/18/2005 10/28/2005 $0 $0 $0 11/02/2005 L - State Settlement  

Investigation Summary

Investigation Nr: 202364873
Event: 06/01/2005
Employee Is Crushed and Pinned by a High Lift Bucket

At approximately 12:30 a.m. on June 1, 2005, Employee #1 was repairing a high lift bucket. Employee #1 fully disconnected and removed one hydraulic hose line that ruptured on the left side of the loader bucket. Employee #1 tipped the half filled bucket of beauty back forward far enough to allow him access to the hose connections on the hydraulic cylinder rams, while still keeping the contents of the bucket in tact. Employee #1 removed the ruptured line which was connected to the top of the cylinder. The line to the top of the cylinder controlled the retraction of the ram and causes the bucket to roll back towards the loader. Since the lower hose was still connected and charged with fluid, the bucket stayed in the tipped forward position. Employee #1 left the hydraulic hose that was attached to the bottom of the cylinder in place as it had been replaced 30 days prior and was still in good condition. Employee #1 then moved to the right side of the machine and began removing the hydraulic hose fittings in order to remove and replace the hoses on the right side. Both of the hoses on the right side were well worn with several years of use and needed to be replaced before they failed also. Employee #1 removed the line to the top of the hydraulic cylinder on the right side and again the bucket did not move from the tipped forward position as the lower portion of the cylinder was stilled charged with hydraulic fluid. Employee #1 removed the hose connected to the lower portion of the right side bucket control ram, and both of the bucket cylinders rams lost pressure and the bucket fell back, pinning and crushing him between the back of the bucket and the frame work of the loader arms.

Keywords: REPAIR, CYLINDER, LOADER BUCKET, PINNED, EQUIPMENT OPERATOR, HYDRAULIC FLUID, HOSE, HYDRAULIC LINE, RUPTURE, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 309007938 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.