Inspection Detail
Inspection: 308784594 - Masco Contractor Svcs.Dba Eastern Insulation
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Masco Contractor Svcs.Dba Eastern Insulation
106 Willis Ave
Atlantic Beach, NC 28512
Mailing Address:
P. O. Box 3217, New Bern, NC 28564
Union Status: NonUnion
SIC:1761
NAICS: 238170/Siding Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/15/2005
Planning Guide: Safety-Construction
Emphasis: S:Program Improvements
Case Closed: 02/13/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100356799 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $5,600 | $0 | $0 | $0 | $0 | $5,600 |
| Current Penalty | $5,040 | $0 | $0 | $0 | $0 | $5,040 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260416 A01 | 11/21/2005 | 11/29/2005 | $2,835 | $3,150 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19260416 A03 | 11/21/2005 | 11/29/2005 | $0 | $0 | $0 | I - Informal Settlement | ||
| 3. | 01002A | Serious | 19261053 B12 | 11/21/2005 | 11/29/2005 | $2,205 | $2,450 | $0 | I - Informal Settlement | ||
| 4. | 01002B | Serious | 19260021 B02 | 11/21/2005 | 11/29/2005 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 11:18 a.m. on August 11, 2005, Employee #1 was part of a crew installing gutters and downspouts at a house under construction in Atlantic Beach, NC. He was on a ladder when he touched a 7,200-volt power line with a piece of aluminum downspout. Employee #1 was knocked off the ladder by the shock and fell 25 ft onto the concrete floor, striking the back of his head on the floor as he landed. Employee #1 was not breathing when Emergency Services arrived, but they were able to revive him. Employee #1 was transported to the hospital, where he died 5:00 p.m. that same day.
Keywords: HEAD, INSTALLING, OVERHEAD POWER LINE, WORK RULES, STRUCK AGAINST, CONSTRUCTION, ELEC CIRC PART--MISC, ELECTRIC SHOCK, FALL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 308784594 | Fatality | Electric Shock | Construction trades, n.e.c. |