Inspection Detail
Inspection: 308682996 - Vala'S Pumpkin Farm And Fall Festival Inc.
Inspection Information - Office: Omaha Area Office
Site Address:
Vala'S Pumpkin Farm And Fall Festival Inc.
12102 S. 180th Street
Gretna, NE 68028
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7999
NAICS: 713990/All Other Amusement and Recreation Industries
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/26/2006
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/13/2006
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 200057362 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
Current Penalty | $2,250 | $0 | $0 | $0 | $0 | $2,250 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100303 B01 | 09/27/2006 | 10/16/2006 | $675 | $1,350 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100305 E01 | 09/27/2006 | 10/16/2006 | $900 | $1,800 | $0 | I - Informal Settlement | ||
3. | 01003A | Serious | 19101200 E01 | 09/27/2006 | 10/16/2006 | $675 | $1,350 | $0 | I - Informal Settlement | ||
4. | 01003B | Serious | 19101200 H | 09/27/2006 | 10/30/2006 | $0 | $0 | $0 | - | ||
5. | 02001 | Other | 19040029 A | 09/27/2006 | 10/30/2006 | $0 | $0 | $0 | - |
Investigation Summary
At approximately 3:20 p.m. on September 23, 2006, Employee #1 was attempting to light a propane-gas-fueled turkey leg roaster with a long-handled lighter. The roaster had been custom built by a local heating and air conditioning contractor and used a water heater control module for burner control. Employee #1 activated the pilot primer valve, which emits propane gas from the pilot located in the center of the main burner. He held the valve open, which allowed propane to build up within the base of the roaster. Employee #1 then tried unsuccessfully to reach the pilot through a small hole in the front of the unit. The accumulated gas reached the flame of the lighter and ignited. Employee #1 was hospitalized with first- and second-degree burns on his left hand, arm, and head. The roaster had no manufacturer's data and there were no written instructions for its use. The normal lighting procedure requires an employee to reach into the roaster through the oven area, where the burner is easily accessible, rather than through the hole Employee #1 attempted to use. The investigation revealed that Employee #1 was not trained in this normal lighting procedure.
Keywords: BURN, PILOT LIGHT, HEAD, FOOD PREPARATION, OVEN, WORK RULES, LIGHTING, PROPANE, UNTRAINED, HAND
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 308682996 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |