Powered by GoogleTranslate

Inspection Detail

Inspection: 308510288 - Powell Water Manufacturing Corporation

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 308510288
Report ID: 0522000
Date Opened: 01/24/2005

Site Address:
Powell Water Manufacturing Corporation
537 Grandin Road
Mainville, OH 45039

Mailing Address:
19331 Tufts Circle, Centennial, CO 80015

Union Status: NonUnion

SIC:3823

NAICS: 334513/ Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/28/2005

Emphasis:

Case Closed: 01/09/2006


Related Activity
Type Activity Nr Safety Health
Accident 101961233
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $2,500 $0 $0 $0 $0 $2,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100134 D01 III 06/29/2005 07/26/2005 $800 $1,500 $0 07/27/2005 F - Formal Settlement  
2. 01002A Serious 19101200 H01 06/29/2005 07/26/2005 $800 $1,500 $0 07/27/2005 F - Formal Settlement  
3. 01002B Serious 19101200 H03 II 06/29/2005 07/26/2005 $0 $0 $0 07/27/2005 F - Formal Settlement  
4. 01002C Serious 19101200 H03 IV 06/29/2005 07/26/2005 $0 $0 $0 07/27/2005 F - Formal Settlement  
5. 01002D Serious 19101200 E01 06/29/2005 07/12/2005 $0 $0 $0 07/27/2005 F - Formal Settlement  
6. 01003A Serious 19101000 A02 06/29/2005 07/05/2005 $900 $1,500 $0 07/27/2005 F - Formal Settlement  
7. 01003B Serious 19101000 E 06/29/2005 07/05/2005 $0 $0 $0 07/27/2005 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201954104
Event: 01/21/2005
Four Employees Injured When Exposed to Arsine Gas

During the afternoon of January 21, 2005, four employees were working in a room containing equipment that was designed to use an electro-coagulation system to remove arsenic from process water. Adjustments to the system were being implemented to increase the speed of arsenic coagulation. By the following morning all four workers were passing urine which was blood red in color, and all four had been admitted into hospitals. The inhalation of Arsine gas caused the symptoms and adverse medical consequences which have been exhibited by these four employees. Excessive levels of Arsenic have been found in their systems. The leading theory concerning the mechanism of generation of Arsine gas was that nascent hydrogen could form when an electric current flowed through an aqueous solution containing substantial concentrations of electrolytes. This hydrogen could react with the arsenic present in this solution to form arsine gas. The workers who suffered the most severe medical consequences spent prolonged periods of time on an elevated platform, looking directly down into the Electro-Coagulation Unit, and making observations as various adjustments were made to the process, such as changes in the amperage of electric current flowing through the process liquid which contained dissolved compounds of arsenic. The use of sulfuric acid to periodically clean the unit and the iron plates which it contained might also have been a contributing factor. Two of the four hospitalized workers displayed little or no functioning of the kidneys and underwent dialysis.

Keywords: INHALATION, AIR CONTAMINATION, GAS, CHEMICAL VAPOR, KIDNEY, POISONING, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308510288 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 308510288 Hospitalized injury Poisoning(Systemic) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close