Powered by GoogleTranslate

Inspection Detail

Inspection: 308508415 - Suntec Concrete, Inc.

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 308508415
Report ID: 0950411
Date Opened: 12/30/2004

Site Address:
Suntec Concrete, Inc.
1919 Sky Harbor Circle South
Phoenix, AZ 85034

Mailing Address:
2221 West Shangri-La Road, Phoenix, AZ 85029

Union Status: NonUnion

SIC:1771

NAICS: 238110/Poured Concrete Foundation and Structure Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 02/08/2005

Emphasis:

Case Closed: 04/27/2005


Related Activity
Type Activity Nr Safety Health
Accident 101993533
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $4,250 $0 $0 $0 $0 $4,250
Current Penalty $4,250 $0 $0 $0 $0 $4,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260703 A01 04/12/2005 04/15/2005 $4,250 $4,250 $0 -  
2. 02001 Other 19260703 A02 04/12/2005 05/03/2005 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201991486
Event: 12/30/2004
Eleven Employees Are Injured in Deck Collapse

Employees #1 though #11, of Suntec Concrete Constructors, Inc., were pouring the concrete into wood forms using a concrete pumping truck. According to employee interviews, approximately 340 cubic yards had been poured when the deck collapsed and all 11 employees fell approximately 30 feet. Employees #1 through #11 were transported to the hospital for treatment of a wide range of injuries including broken arms, serious lacerations, and contusions. Employees #1, #6, and #8 were hospitalized. The area that collapsed was the southeast corner or Pour 17 which is the 4th floor deck. According to the design, under Pour 17, a third floor was not installed. Shoring towers supporting the deck spanned approximately 25 feet to the bottom of the forms. The entire deck collapsed including the plywood forms, rebar mat, and tensioning cables. The forms being filled were supported by Atlas All-speed shoring and Dako single post shores placed along with wood post shores. The specific beams that collapsed are identified on the architectural plans as beams PG-9, PB-4E, and PB-4C.

Keywords: DECKING, CONCRETE FORM WORK, FRACTURE, COLLAPSE, STRUCK AGAINST, CONSTRUCTION, FALL, CONCRETE, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308508415 Non Hospitalized injury Cut/Laceration Concrete and terrazzo finishers
2 308508415 Hospitalized injury Bruise/Contus/Abras Concrete and terrazzo finishers
3 308508415 Hospitalized injury Fracture Concrete and terrazzo finishers
4 308508415 Non Hospitalized injury Strain/Sprain Concrete and terrazzo finishers
5 308508415 Non Hospitalized injury Concussion Concrete and terrazzo finishers
6 308508415 Hospitalized injury Fracture Concrete and terrazzo finishers
7 308508415 Non Hospitalized injury Strain/Sprain Concrete and terrazzo finishers
8 308508415 Hospitalized injury Bruise/Contus/Abras Concrete and terrazzo finishers
9 308508415 Non Hospitalized injury Bruise/Contus/Abras Concrete and terrazzo finishers
10 308508415 Non Hospitalized injury Bruise/Contus/Abras Concrete and terrazzo finishers
11 308508415 Non Hospitalized injury Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close