Inspection Detail
Inspection: 308451848 - Ingersoll-Rand Company
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Ingersoll-Rand Company
711 Corporate Center Court
Westminster, MD 21157
Mailing Address:
9100 Yellow Brick Road, Suite M, Baltimore, MD 21237
Union Status: NonUnion
SIC:3563
NAICS: 333912/Air and Gas Compressor Manufacturing
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/10/2005
Emphasis: S:General Industry, S:Struck-By
Case Closed: 07/03/2007
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102357035 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 2 | 2 | ||||
Initial Penalty | $2,975 | $0 | $0 | $0 | $0 | $2,975 |
Current Penalty | $0 | $0 | $0 | $1,190 | $0 | $1,190 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Other | 19100147 C04 I | 02/17/2005 | 03/22/2005 | $1,190 | $2,975 | $0 | 02/23/2005 | F - Formal Settlement | |
2. | 01001B | Other | 19100147 C05 I | 02/17/2005 | 02/22/2005 | $0 | $0 | $0 | 02/23/2005 | F - Formal Settlement | |
3. | 01001C | Other | 19100147 F02 I | 02/17/2005 | 03/22/2005 | $0 | $0 | $0 | 02/23/2005 | F - Formal Settlement | |
4. | 02001 | Other | 19100147 C07 IV | 02/17/2005 | 02/23/2005 | $0 | $0 | $0 | 02/23/2005 | F - Formal Settlement |
Investigation Summary
On December 15, 2004, Employee #1 and coworkers were installing a new compressor system. While they were pressuring the system with air to make tests and adjustments, an air line component broke free and struck Employee #1's right shoulder. He was treated at a local hospital for a severe contusion. Investigation revealed that the compressor system had electrical and pneumatic hazardous energy sources, and the employer presented no written hazardous energy control procedure for the operation they performed. The employer also had no device to lockout pneumatic energy and did not communicate their lockout/tagout procedures to their client.
Keywords: COMPRESSOR, SHOULDER, WORK RULES, COMPRESSED AIR, LOCKOUT, PRESSURE PIPING, HIGH PRESSURE, STRUCK BY, PRESSURE RELEASE, CONTUSION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 308451848 | Non Hospitalized injury | Bruise/Contus/Abras | Industrial machinery repairers |