Powered by GoogleTranslate

Inspection Detail

Inspection: 308451848 - Ingersoll-Rand Company

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 308451848
Report ID: 0352450
Date Opened: 12/17/2004

Site Address:
Ingersoll-Rand Company
711 Corporate Center Court
Westminster, MD 21157

Mailing Address:
9100 Yellow Brick Road, Suite M, Baltimore, MD 21237

Union Status: NonUnion

SIC:3563

NAICS: 333912/Air and Gas Compressor Manufacturing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/10/2005

Emphasis: S:General Industry, S:Struck-By

Case Closed: 07/03/2007


Related Activity
Type Activity Nr Safety Health
Accident 102357035
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $2,975 $0 $0 $0 $0 $2,975
Current Penalty $0 $0 $0 $1,190 $0 $1,190
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 19100147 C04 I 02/17/2005 03/22/2005 $1,190 $2,975 $0 02/23/2005 F - Formal Settlement  
2. 01001B Other 19100147 C05 I 02/17/2005 02/22/2005 $0 $0 $0 02/23/2005 F - Formal Settlement  
3. 01001C Other 19100147 F02 I 02/17/2005 03/22/2005 $0 $0 $0 02/23/2005 F - Formal Settlement  
4. 02001 Other 19100147 C07 IV 02/17/2005 02/23/2005 $0 $0 $0 02/23/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202355681
Event: 12/15/2004
Employee Is Injured When Struck by Equipment Component

On December 15, 2004, Employee #1 and coworkers were installing a new compressor system. While they were pressuring the system with air to make tests and adjustments, an air line component broke free and struck Employee #1's right shoulder. He was treated at a local hospital for a severe contusion. Investigation revealed that the compressor system had electrical and pneumatic hazardous energy sources, and the employer presented no written hazardous energy control procedure for the operation they performed. The employer also had no device to lockout pneumatic energy and did not communicate their lockout/tagout procedures to their client.

Keywords: COMPRESSOR, SHOULDER, WORK RULES, COMPRESSED AIR, LOCKOUT, PRESSURE PIPING, HIGH PRESSURE, STRUCK BY, PRESSURE RELEASE, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308451848 Non Hospitalized injury Bruise/Contus/Abras Industrial machinery repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.