Powered by GoogleTranslate

Inspection Detail

Inspection: 308437631 - Roads, Inc. Of Nwf

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 308437631
Report ID: 0419700
Date Opened: 04/26/2006

Site Address:
Roads, Inc. Of Nwf
Gardenia Circle
Pensacola, FL 32534

Mailing Address:
106 Stone Blvd., Cantonment, FL 32533

Union Status: NonUnion

SIC:1623

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 06/29/2006

Emphasis: L:Ohpwrlne, N:Trench, S:Construction Fatalities

Case Closed: 10/15/2007


Related Activity
Type Activity Nr Safety Health
Accident 101355428
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 4 3 7
Initial Penalty $10,150 $132,000 $0 $0 $0 $142,150
Current Penalty $6,090 $79,200 $0 $0 $0 $85,290
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 10/10/2006 11/03/2006 $1,050 $1,750 $0 I - Informal Settlement  
2. 01002 Serious 19260100 A 10/10/2006 10/13/2006 $1,050 $1,750 $0 I - Informal Settlement  
3. 01003 Serious 19260651 D 10/10/2006 10/13/2006 $1,050 $1,750 $0 I - Informal Settlement  
4. 01004 Serious 19260651 G01 I 10/10/2006 10/13/2006 $2,940 $4,900 $0 I - Informal Settlement  
5. 02001 Willful 19260550 A15 I 10/10/2006 10/13/2006 $26,400 $44,000 $0 I - Informal Settlement  
6. 02002 Willful 19260651 J02 10/10/2006 10/13/2006 $26,400 $44,000 $0 I - Informal Settlement  
7. 02003 Willful 19260652 A01 10/10/2006 10/13/2006 $26,400 $44,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201353083
Event: 04/25/2006
Employee Dies in Natural Gas Explosion

On April 19, 2006, Employee #1 and his crew were installing storm drainage pipes in an older neighborhood. During the installation of the drainage pipes, damage had been caused on the existing natural gas pipe lines in the neighborhood. The odor of gas was present prior to the day of the installation, and the local gas company had been contacted to identify and repair the leaks. The smell of gas was still present and noticed by the supervisor, employees and others; however, the supervisor did not contact the gas company to investigate the odor, and to locate the leak. The supervisor also did not remove the employees from the excavation where the gas odor existed, and did not test the atmosphere of the excavation to determine if there was a hazardous atmosphere or condition in the excavation. The supervisor directed Employee #1 to enter the 48-inch diameter drainage pipe line to retrieve a laser surveying machine that was located approximately 90 feet within the pipe line. Natural gas that had escaped from two breaks in the gas line had accumulated within the storm drain pipe line. While Employee #1 was in the pipe line, the natural gas within it ignited. The specific ignition source was not identified. Even though severely burned, Employee #1 was able to exit the storm drain pipe line, and was taken to the hospital. Six days later, he died as a result of his injuries.

Keywords: BURN, INSTALLING, VAPOR, DRAIN PIPE, FIRE, CAUGHT BY, CONSTRUCTION, EXPLOSION, SMOKE, GAS LEAK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308437631 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.