Powered by GoogleTranslate

Inspection Detail

Inspection: 308430719 - Jones Masonry Contractors, Inc.

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 308430719
Report ID: 0419700
Date Opened: 04/13/2005

Site Address:
Jones Masonry Contractors, Inc.
608 Lost Key Drive
Perdido Key, FL 32507

Mailing Address:
1907 Pass Road, Suite C, Biloxi, MS 39531

Union Status: NonUnion

SIC:1741

NAICS: 238140/Masonry Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 04/15/2005

Emphasis: L:Fall, S:Construction Fatalities

Case Closed: 01/25/2006


Related Activity
Type Activity Nr Safety Health
Accident 101354488
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations
Initial Penalty $4,900 $0 $0 $0 $0 $4,900
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260502 B03 07/25/2005 07/28/2005 $0 $4,900 $0 08/08/2005 F - Formal Settlement Citation has been deleted.
2. 02001 Other 19260502 B02 07/25/2005 07/28/2005 $0 $0 $0 08/08/2005 F - Formal Settlement Citation has been deleted.
3. 02002 Other 19260502 B09 07/25/2005 07/28/2005 $0 $0 $0 08/08/2005 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201352705
Event: 04/12/2005
Employee Falls from Elevated Platform and Is Killed

On April 12, 2005, an employee and two coworkers were waiting on the seventh floor for the bucket elevator to arrive. One employee bent over the top rail (wire rope) of the guardrail system to look to see where the elevator was. When the employee put his hands on the top rail and leaned against the wire rope, it loosened from its end connections, and the employee fell approximately 61 ft to his death. Employees from another company (Roy Anderson Corp.) had incorrectly secured the ends of the wire rope rails to their anchor points. The wire rope rail was not capable of withstanding the force of a man (weighing approximately 200 lbs) leaning against it. The employees who erected the wire rope guardrail system were not experienced in erecting it.

Keywords: UNTRAINED, GUARDRAIL, FALL, ANCHOR, WORK RULES, EQUIPMENT FAILURE, WIRE ROPE, STEEL CONNECTOR, UNSTABLE POSITION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308430719 Fatality Bruise/Contus/Abras Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.