Inspection Detail
Inspection: 308153568 - Jerry'S Pump Service
Inspection Information - Office: Naperville Area Office
Site Address:
Jerry'S Pump Service
3 S 448 2nd Street
Warrenville, IL 60555
Mailing Address:
109 2nd Street, Downers Grove, IL 60515
Union Status: NonUnion
SIC:1711
NAICS: 238910/Site Preparation Contractors
Inspection Type: Accident
Scope: No Insp/Other
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/15/2005
Emphasis:
Case Closed: 09/16/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100821362 |
Investigation Summary
On September 9, 2005, Employee #1 and his wife were replacing a pressure tank, an apparatus resembling a personal water tower. She turned on the power to see if the tank was functional and if water was entering it. Employee #1 was reaching to shut off the valve when he brushed against the power switch and was electrocuted. His wife then unplugged the power to the tank. Employee #1's body was transported by paramedics to Central DuPage Hospital.
Keywords: INSTALLING, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, ELEC CIRC PART--MISC, WATER TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 308153568 | Fatality | Electric Shock | Occupation not reported |