Inspection Detail
Inspection: 308066174 - The Rosel Company
Inspection Information - Office: Oklahoma City Area Office
Site Address:
The Rosel Company
11 Miles N.,2 Miles E.,1/2 Mile N. Of Four Corners
Guymon, OK 73942
Mailing Address:
302 S Clay Ave., Liberal, KS 67901
Union Status: NonUnion
SIC:1389
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/29/2005
Emphasis: L:Oilgas
Case Closed: 03/08/2006
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100644343 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $8,500 | $0 | $0 | $0 | $0 | $8,500 |
Current Penalty | $7,500 | $0 | $0 | $0 | $0 | $7,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 02/01/2006 | 03/06/2006 | $2,500 | $2,500 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100109 E04 IV | 02/01/2006 | 03/06/2006 | $3,000 | $3,500 | $0 | I - Informal Settlement | ||
3. | 01003A | Serious | 19100332 B01 | 02/01/2006 | 03/06/2006 | $2,000 | $2,500 | $0 | I - Informal Settlement | ||
4. | 01003B | Serious | 19100333 A | 02/01/2006 | 03/06/2006 | $0 | $0 | $0 | - |
Investigation Summary
On September 12, 2005, Employees #1 and #2 were conducting oil and gas well wire line activities in the conversion of a well into an injection disposal well. They had logged the well, set an explosive bridge plug, and cemented the plug. They prepared an electrically initiated perforating gun that consisted of 36 shape charges in an 11-ft-long steel tube that was to be lowered into the well. The gun accidently discharged, and Employee #1 was hit with at least one charge on the upper thighs, which nearly severed both legs. Employee #2 was blown back onto the service rig floor and wellhead area. He had shrapnel wounds over his entire body and sustained nerve damage to a leg. Both employees were airlifted to a hospital. Employee #1 died upon arrival, and Employee #2 was treated and hospitalized until the next day. After he was released he required further medical treatment. The wire line was still energized from the prior logging activity and a check for the presence of electrical energy on the wire line was not conducted. This test would have shown electrical energy present on the wire line center conductor, and in all likelihood would have prevented the accident.
Keywords: WELL SERVICE RIG, EXPLOSIVES, WELL, TORSO, PERFORATING GUN, OIL WELL SERVICING, STRUCK BY, LEG, OIL WELL PERFORATING, PUNCTURE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 308066174 | Fatality | Other | Occupation not reported | ||
2 | 308066174 | Hospitalized injury | Puncture | Occupation not reported |