Inspection Detail
Inspection: 308015700 - Alabama Power Company
Inspection Information - Office: Birmingham Area Office
Site Address:
Alabama Power Company
County Road 422
Shelby, AL 35143
Mailing Address:
P.O. Box 2641, Birmingham, AL 35291
Union Status: Union
SIC:4911
NAICS: 221122/Electric Power Distribution
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/16/2005
Emphasis: L:Ohpwrlne
Case Closed: 04/11/2005
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101273027 |
Investigation Summary
A power line worker was operating an Autocar Norstar AE Series 95 aerial lift. The articulating, extensible boom had a reach of approximately 30 meters. Its base plate was secured by 18, grade 8, 19-millimeter-diameter bolts. The line worker had removed a temporary ground from an overhead power line so that he could reenergize the line. As he was lowering the platform, the boom turntable separated from the turret base plate. He was catapulted from the platform, landing approximately 27 meters from the front of the vehicle. He died of injuries sustained in the fall.
Keywords: PLATFORM, BOOM, EQUIPMENT FAILURE, BOLT, FALL, SHEARED, AERIAL LIFT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 308015700 | Fatality | Other | Electrical power installers and repairers |