Inspection Detail
Inspection: 307931741 - Alstom Caribe Inc
Inspection Information - Office: Pr-E-San Juan 0257260
Site Address:
Alstom Caribe Inc
Calle Mercado Central Esq 28 Zona Portuaria
San Juan, PR 00936
Mailing Address:
1757 Ave Paz Granela Urb Santiago Iglesias, San Juan, PR 00921
Union Status: NonUnion
SIC:1711
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/13/2007
Emphasis:
Case Closed: 08/22/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100170760 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 6A0001 | 03/26/2007 | 03/29/2007 | $2,500 | $3,500 | $0 | 04/18/2007 | F - Formal Settlement |
Investigation Summary
Employee #1 was performing hydrostatic test when a pressure valve broke and hit him causing a concussion and his death.
Keywords: HEAD, EQUIPMENT FAILURE, PRESSURE PIPING, STRUCK BY, CONCUSSION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 307931741 | Fatality | Concussion | Occupation not reported |